Fire safety measures in the industry include fire alarms, fire extinguishers, emergency exits, and regular fire drills.
Installation of fire alarms to detect smoke or fire
Availability of fire extinguishers at strategic locations
Clear marking of emergency exits for quick evacuation
Regular fire drills to educate employees on evacuation procedures
Proper storage of flammable materials to prevent fire hazards
A Direct-on-Line (DOL) starter is a type of motor starter that directly connects the motor to the power supply at full voltage.
DOL starters are used for small motors that do not require soft starting or speed control.
When the DOL starter is switched on, the motor is connected directly to the power supply at full voltage.
This can cause a high inrush current, which may lead to voltage dips in the power supply.
DOL st...
Key principles of industrial safety include hazard identification, risk assessment, training, and proper use of personal protective equipment.
Hazard identification: Recognizing potential dangers in the workplace such as exposed wires or slippery floors.
Risk assessment: Evaluating the likelihood and severity of potential hazards to determine the best course of action.
Training: Providing employees with proper safety...
The standard voltage for control circuits is typically 24 volts.
Standard voltage for control circuits is usually 24 volts
Higher voltages like 120V or 240V can also be used for control circuits in some cases
Lower voltages like 12V or 5V may be used for specific applications
Key principles of electrical safety include proper training, equipment maintenance, hazard identification, and following safety procedures.
Proper training on electrical systems and equipment is essential to prevent accidents.
Regular maintenance of electrical equipment and tools helps ensure safe operation.
Identifying potential electrical hazards such as exposed wires or overloaded circuits is crucial.
Following saf...
I applied via Naukri.com and was interviewed in Dec 2024. There were 4 interview rounds.
Key principles of industrial safety include hazard identification, risk assessment, training, and proper use of personal protective equipment.
Hazard identification: Recognizing potential dangers in the workplace such as exposed wires or slippery floors.
Risk assessment: Evaluating the likelihood and severity of potential hazards to determine the best course of action.
Training: Providing employees with proper safety trai...
Key principles of electrical safety include proper training, equipment maintenance, hazard identification, and following safety procedures.
Proper training on electrical systems and equipment is essential to prevent accidents.
Regular maintenance of electrical equipment and tools helps ensure safe operation.
Identifying potential electrical hazards such as exposed wires or overloaded circuits is crucial.
Following safety p...
Fire safety measures in the industry include fire alarms, fire extinguishers, emergency exits, and regular fire drills.
Installation of fire alarms to detect smoke or fire
Availability of fire extinguishers at strategic locations
Clear marking of emergency exits for quick evacuation
Regular fire drills to educate employees on evacuation procedures
Proper storage of flammable materials to prevent fire hazards
I possess strong verbal and written communication skills, with the ability to effectively convey information and collaborate with team members.
Strong verbal communication skills
Effective written communication skills
Ability to convey information clearly and concisely
Collaboration with team members
Active listening skills
To change the rotation of an induction motor, swap any two of the three power supply wires.
Swap any two of the three power supply wires to change the rotation direction of the motor.
Ensure the motor is disconnected from the power supply before making any changes.
Consult the motor's manual or a professional if unsure about the correct wiring configuration.
The standard voltage for control circuits is typically 24 volts.
Standard voltage for control circuits is usually 24 volts
Higher voltages like 120V or 240V can also be used for control circuits in some cases
Lower voltages like 12V or 5V may be used for specific applications
A Direct-on-Line (DOL) starter is a type of motor starter that directly connects the motor to the power supply at full voltage.
DOL starters are used for small motors that do not require soft starting or speed control.
When the DOL starter is switched on, the motor is connected directly to the power supply at full voltage.
This can cause a high inrush current, which may lead to voltage dips in the power supply.
DOL starter...
Motor resistance can be measured using a multimeter set to the resistance or ohms setting.
Set the multimeter to the resistance or ohms setting
Disconnect the motor from the power source
Connect the multimeter leads to the motor terminals
Read the resistance value displayed on the multimeter
Compare the measured resistance value to the motor's specifications
Top trending discussions
posted on 15 May 2018
posted on 19 May 2017
I appeared for an interview in Oct 2016.
Alumina is obtained from bauxite through the Bayer process.
Bauxite is crushed and mixed with sodium hydroxide to form a slurry.
The slurry is heated and pressurized in a digester to dissolve the alumina content.
The resulting solution is cooled and filtered to remove impurities.
The purified solution is then heated to precipitate the alumina as a white powder.
The alumina powder is washed, dried, and calcined to produce pu...
The reaction for Al extraction from alumina involves the reduction of alumina using carbon or electrolysis.
Alumina (Al2O3) is first converted into aluminum chloride (AlCl3) by reacting with hydrochloric acid.
The aluminum chloride is then reduced to aluminum metal by either carbon reduction or electrolysis.
In carbon reduction, carbon (usually in the form of coke) is heated with the aluminum chloride to produce aluminum ...
There are four main types of cast iron: gray iron, white iron, ductile iron, and malleable iron.
Gray iron is the most common type and has excellent castability and good machinability.
White iron is very hard and brittle, often used for wear-resistant applications.
Ductile iron has high strength and ductility, making it suitable for a wide range of applications.
Malleable iron is heat-treated to improve its strength and du...
I applied via Recruitment Consultant and was interviewed in Nov 2019. There were 3 interview rounds.
Mining is the process of extracting valuable minerals or other geological materials from the earth's surface or underground.
Mining is done to obtain various resources such as coal, gold, diamonds, and metals like iron, copper, and aluminum.
It involves the removal of soil, rocks, and other materials to access the desired minerals.
Mining can be categorized into surface mining and underground mining, depending on the loca...
I applied via Recruitment Consulltant and was interviewed before Oct 2021. There were 4 interview rounds.
posted on 13 Jan 2022
I appeared for an interview in Dec 2021.
MGND stands for Main Ground. It refers to the primary grounding point in an electrical system.
MGND is the main grounding point in an electrical system.
It is typically connected to the earth ground to provide a safe path for electrical current to flow in case of a fault.
MGND helps protect equipment and personnel from electrical shocks.
It is an essential component in ensuring electrical safety and proper functioning of t...
Grounding negative in inverters helps in reducing electromagnetic interference (EMI) and noise.
Grounding negative in inverters helps in reducing EMI and noise.
It also helps in improving the efficiency of the inverter.
Grounding negative is done to provide a reference point for the inverter's output voltage.
It also helps in protecting the inverter from voltage spikes and surges.
Examples of inverters that use negative gro...
I applied via Approached by Company and was interviewed before May 2021. There were 2 interview rounds.
I applied via Campus Placement and was interviewed before Sep 2021. There were 4 interview rounds.
Basic Maths, Science & Gk
Indian economy - 10 min
Air conditioning is the process of altering the properties of air to make it more comfortable, while refrigeration is the process of removing heat from a space or substance.
Air conditioning is used to cool and dehumidify indoor air for comfort.
Refrigeration is used to preserve food, medicine, and other perishable items.
Air conditioning uses a refrigerant to absorb heat from indoor air and release it outside.
Refrigerati...
Material properties and usage are crucial in determining the performance and durability of products in the real world.
Material properties such as strength, durability, and conductivity are important considerations in product design and development.
Different materials have different properties and are suited for different applications. For example, steel is strong and durable, making it ideal for construction and manufa...
Heat conduction is the transfer of heat through a material, while radiation is the transfer of heat through electromagnetic waves.
Heat conduction occurs in solids and liquids, while radiation can occur in vacuum or through transparent media.
Heat conduction is slower than radiation.
Examples of heat conduction include touching a hot stove or holding a warm cup of coffee, while examples of radiation include feeling the wa...
I applied via Walk-in and was interviewed before Apr 2020. There was 1 interview round.
The type of breaker used depends on the electrical load and the circuit requirements.
The most common types of breakers are standard, AFCI, GFCI, and dual-function.
Standard breakers are used for general-purpose circuits.
AFCI breakers are used for circuits that power bedrooms and living rooms.
GFCI breakers are used for circuits that power bathrooms, kitchens, and outdoor areas.
Dual-function breakers combine AFCI and GFCI...
Conductors are materials that allow electricity to flow through them. There are different types of conductors used in electrical systems.
Copper is the most commonly used conductor in electrical wiring
Aluminum is also used as a conductor, especially in high voltage power transmission
Silver is the best conductor, but it is too expensive for most applications
Gold is also a good conductor, but it is even more expensive tha...
I applied via Campus Placement and was interviewed before Sep 2021. There were 2 interview rounds.
G.k,maths,english helth, wait, hight
based on 1 interview experience
Difficulty level
Duration
Assistant Manager
467
salaries
| ₹9.2 L/yr - ₹15.9 L/yr |
Manager
296
salaries
| ₹14.6 L/yr - ₹27 L/yr |
Senior Manager
152
salaries
| ₹18.5 L/yr - ₹32.7 L/yr |
Deputy Manager
148
salaries
| ₹12.3 L/yr - ₹23 L/yr |
Sales Manager
106
salaries
| ₹2.5 L/yr - ₹8.1 L/yr |
Hindalco Industries
Rungta Mines
Vedanta Aluminium
Hindustan Zinc