Motor HP can be calculated using the formula: HP = (Torque x RPM) / 5252
Determine the torque and RPM of the motor
Use the formula: HP = (Torque x RPM) / 5252
For example, if a motor has a torque of 50 lb-ft and an RPM of 3,000, the HP would be (50 x 3000) / 5252 = 28.6 HP
An air compressor works by converting power into potential energy stored in compressed air.
Check the oil level and drain the water from the tank before use
Connect the air hose to the compressor and the tool you want to use
Turn on the compressor and wait for it to build pressure
Adjust the pressure regulator to the desired level
Turn off the compressor and disconnect the air hose when finished
KVARH and KVA can be calculated using different formulas based on the type of circuit and load.
For single-phase circuits, KVA = voltage x current x power factor
For three-phase circuits, KVA = voltage x current x 1.732 x power factor
KVARH is calculated by integrating the reactive power over time
KVARH = (KVAR x hours of operation) / 1000
KVAR can be calculated using the Pythagorean theorem: KVAR = sqrt(KVA^2 - KW^2)
Power factor is the ratio of real power to apparent power in an AC circuit.
Power factor can be improved by using capacitors or inductors in the circuit.
A high power factor means more efficient use of electricity.
Low power factor can result in penalties from utility companies.
Power factor correction is important in industrial and commercial settings.
Power factor is measured on a scale of 0 to 1, with 1 being ideal.
MIG/MAG welding machine is a type of welding equipment that uses a consumable wire electrode to create an electric arc for welding.
MIG stands for Metal Inert Gas while MAG stands for Metal Active Gas.
The machine uses a shielding gas to protect the weld from atmospheric contamination.
It is commonly used in automotive and manufacturing industries.
MIG/MAG welding is known for its speed and versatility.
The machine can...
Chock, Ignitor, and Capacitor are electrical components used in various applications.
A chock is an inductor used to limit the flow of current in an electrical circuit.
An ignitor is a device used to ignite fuel in combustion engines or lamps.
A capacitor is an electrical component used to store energy in an electric field.
All three components are commonly used in lighting systems, power supplies, and electronic devi...
Star delta connection is a method of connecting three-phase electrical motors.
Used to reduce starting current and torque
Star connection for starting, delta connection for running
Commonly used in industrial applications
Requires a special motor starter
Reduces stress on motor windings
Dial starter connection diagrams are used to show the wiring connections for a dial starter.
The diagrams typically show the power supply connections, control circuit connections, and motor connections.
The power supply connections include the incoming power and the power going to the motor.
The control circuit connections include the start and stop buttons, overload protection, and any other control devices.
The moto...
I applied via Company Website and was interviewed before May 2019. There were 4 interview rounds.
Dial starter connection diagrams are used to show the wiring connections for a dial starter.
The diagrams typically show the power supply connections, control circuit connections, and motor connections.
The power supply connections include the incoming power and the power going to the motor.
The control circuit connections include the start and stop buttons, overload protection, and any other control devices.
The motor con...
Star delta connection is a method of connecting three-phase electrical motors.
Used to reduce starting current and torque
Star connection for starting, delta connection for running
Commonly used in industrial applications
Requires a special motor starter
Reduces stress on motor windings
LT stands for Low Tension, CT stands for Current Transformer, HT stands for High Tension.
LT - Low Tension refers to electrical systems operating at voltages below 1,000 volts.
CT - Current Transformer is a type of instrument transformer used to measure alternating current.
HT - High Tension refers to electrical systems operating at voltages above 1,000 volts.
Examples: LT cables, CT meters, HT transformers.
An air compressor works by converting power into potential energy stored in compressed air.
Check the oil level and drain the water from the tank before use
Connect the air hose to the compressor and the tool you want to use
Turn on the compressor and wait for it to build pressure
Adjust the pressure regulator to the desired level
Turn off the compressor and disconnect the air hose when finished
MIG/MAG welding machine is a type of welding equipment that uses a consumable wire electrode to create an electric arc for welding.
MIG stands for Metal Inert Gas while MAG stands for Metal Active Gas.
The machine uses a shielding gas to protect the weld from atmospheric contamination.
It is commonly used in automotive and manufacturing industries.
MIG/MAG welding is known for its speed and versatility.
The machine can be u...
Motor HP can be calculated using the formula: HP = (Torque x RPM) / 5252
Determine the torque and RPM of the motor
Use the formula: HP = (Torque x RPM) / 5252
For example, if a motor has a torque of 50 lb-ft and an RPM of 3,000, the HP would be (50 x 3000) / 5252 = 28.6 HP
Chock, Ignitor, and Capacitor are electrical components used in various applications.
A chock is an inductor used to limit the flow of current in an electrical circuit.
An ignitor is a device used to ignite fuel in combustion engines or lamps.
A capacitor is an electrical component used to store energy in an electric field.
All three components are commonly used in lighting systems, power supplies, and electronic devices.
Power factor is the ratio of real power to apparent power in an AC circuit.
Power factor can be improved by using capacitors or inductors in the circuit.
A high power factor means more efficient use of electricity.
Low power factor can result in penalties from utility companies.
Power factor correction is important in industrial and commercial settings.
Power factor is measured on a scale of 0 to 1, with 1 being ideal.
KVARH and KVA can be calculated using different formulas based on the type of circuit and load.
For single-phase circuits, KVA = voltage x current x power factor
For three-phase circuits, KVA = voltage x current x 1.732 x power factor
KVARH is calculated by integrating the reactive power over time
KVARH = (KVAR x hours of operation) / 1000
KVAR can be calculated using the Pythagorean theorem: KVAR = sqrt(KVA^2 - KW^2)
Top trending discussions
I appeared for an interview before Apr 2024, where I was asked the following questions.
I appeared for an interview in Sep 2024.
Amazing aptitute test with knowledge of all aspects of the industry
Great assessment of all the interview natures of the assignment for risk, protocol, and valuation.
I applied via Walk-in and was interviewed before May 2022. There were 2 interview rounds.
I have executed multiple projects in the last few years.
Developed a new website for a client using HTML, CSS, and JavaScript.
Created a mobile application for a startup using React Native.
Managed a team of developers to build a custom CRM system for a large corporation.
Implemented a data analytics solution for a healthcare organization using Python and SQL.
Designed and executed a social media marketing campaign for a no...
I applied via Job Portal
The percentage of steel in a pile varies depending on the type and design of the pile.
The percentage of steel in a pile can range from 0% to over 90%.
The type of pile (e.g. steel, concrete, timber) and its design (e.g. diameter, length, wall thickness) determine the percentage of steel.
Steel piles typically have a higher percentage of steel than other types of piles.
The percentage of steel in a pile can also affect its...
Pile built-up above cut off level as per IS code
IS code specifies the maximum allowable pile length above cut off level
Pile length above cut off level should not exceed 3 times the pile diameter
Built-up pile above cut off level can cause structural instability and failure
Vertical tolerance for piles as per IS code
As per IS 2911-1:2010, the vertical tolerance for piles is +/- 25mm
This tolerance is applicable for both driven and cast-in-situ piles
The tolerance is measured at the top of the pile and at intervals of 3m along the length
If the deviation exceeds the tolerance limit, the pile may need to be rejected or remedial measures taken
Pile concrete consumption tolerance depends on various factors.
Pile diameter and length
Concrete mix design
Placement method
Quality control measures
Environmental conditions
Tolerance typically ranges from 5-10% of estimated consumption
Regular monitoring and adjustment of concrete consumption is necessary
Unit weight of steel is 7850 kg/m³
The unit weight of steel is the weight of a specific volume of steel
It is measured in kilograms per cubic meter (kg/m³)
The unit weight of steel is 7850 kg/m³
This value may vary slightly depending on the composition and manufacturing process of the steel
I applied via Company Website and was interviewed in Apr 2024. There were 2 interview rounds.
Mathematical round -1.5hours
based on 1 interview experience
based on 1 review
Rating in categories
Production Engineer
27
salaries
| ₹1.2 L/yr - ₹5.2 L/yr |
Engineer
25
salaries
| ₹1.8 L/yr - ₹5.3 L/yr |
Senior Engineer
16
salaries
| ₹4.5 L/yr - ₹9 L/yr |
Assistant Manager
14
salaries
| ₹5.2 L/yr - ₹9 L/yr |
Safety Officer
13
salaries
| ₹3 L/yr - ₹5.4 L/yr |
L&T Energy Hydrocarbon
AECOM
Sterling & Wilson
Apco Infratech