Easy test with simple questions
Solar panels convert sunlight into electricity through the photovoltaic effect.
Solar panels are made up of photovoltaic cells that contain semiconductors like silicon.
When sunlight hits the solar panel, the photons in the light are absorbed by the semiconductors.
This absorption creates an electric current as the electrons in the semiconductors are excited and flow through the material.
The flow of electrons generates el...
The company is a leading provider of electrical engineering solutions for various industries.
Specializes in designing and implementing electrical systems for commercial and industrial buildings
Offers services such as power distribution, lighting design, and energy efficiency consulting
Works with clients in sectors like manufacturing, healthcare, and telecommunications
Has a team of experienced electrical engineers and t...
posted on 17 Apr 2025
I appeared for an interview in Mar 2025, where I was asked the following questions.
posted on 10 Feb 2024
I applied via Campus Placement
The basic law governing transformers is the law of electromagnetic induction.
The law states that when the magnetic field around a conductor changes, an electromotive force (EMF) is induced in the conductor.
This EMF can cause a current to flow if the conductor forms a closed loop.
In a transformer, this principle is used to transfer electrical energy from one circuit to another through electromagnetic induction.
The prima...
Various losses in a transformer include copper losses, iron losses, and stray losses.
Copper losses occur due to resistance in the transformer windings.
Iron losses, also known as core losses, occur due to hysteresis and eddy currents in the transformer core.
Stray losses occur due to leakage flux and stray capacitance in the transformer.
Copper losses and iron losses are the major contributors to total losses in a transfo...
AC and DC are two types of electrical current. AC changes direction periodically while DC flows in one direction.
AC stands for Alternating Current and DC stands for Direct Current.
AC changes direction periodically, typically in a sinusoidal waveform.
DC flows in one direction only, maintaining a constant polarity.
AC is used for power transmission over long distances due to its ability to be easily converted to different...
An inverter is a device that converts DC power to AC power.
An inverter is commonly used in electrical systems to convert the direct current (DC) produced by sources such as batteries or solar panels into alternating current (AC) that can be used to power appliances and devices.
The basic working principle of an inverter involves the use of electronic components such as transistors to switch the DC input on and off rapid...
Solar panel installation requires several components including solar panels, inverters, mounting systems, wiring, and electrical protection devices.
Solar panels: These are the main components that convert sunlight into electricity.
Inverters: They convert the direct current (DC) produced by solar panels into alternating current (AC) that can be used in homes or fed into the grid.
Mounting systems: These are used to secur...
There are various types of circuit breakers with different uses and ratings.
Miniature Circuit Breaker (MCB) - used in residential and commercial buildings
Molded Case Circuit Breaker (MCCB) - used in industrial applications
Air Circuit Breaker (ACB) - used for high voltage applications
Ground Fault Circuit Interrupter (GFCI) - used to protect against electrical shocks
Residual Current Circuit Breaker (RCCB) - used to detec...
I applied via Naukri.com and was interviewed before Jun 2023. There were 3 interview rounds.
dv/dt and du/dt filters manage voltage and current changes in electrical systems, ensuring stability and performance.
dv/dt filter limits the rate of voltage change to protect components from voltage spikes.
Example: Used in motor drives to prevent insulation breakdown.
du/dt filter limits the rate of current change, reducing electromagnetic interference.
Example: Commonly used in power electronics to enhance system reliab...
The gearbox oil grade is typically specified by the manufacturer based on the requirements of the gearbox.
Gearbox oil grade is determined by the viscosity and additives needed for proper lubrication.
Common gearbox oil grades include SAE 80, SAE 90, and SAE 140.
Consult the manufacturer's specifications or maintenance manual for the recommended gearbox oil grade.
Pitch convertor system,
WTG In Reduction refers to Wind Turbine Generator efficiency improvements through various engineering techniques.
Aerodynamic Optimization: Enhancing blade design to improve lift-to-drag ratio, resulting in better energy capture.
Control Systems: Implementing advanced control algorithms to optimize turbine performance under varying wind conditions.
Gearbox Improvements: Using high-efficiency gearboxes to reduce mechanical...
Inox wind turbine generators (WTGs) face issues primarily related to corrosion, mechanical wear, and electrical failures.
Corrosion Resistance: Inox WTGs are designed with stainless steel to resist corrosion, but environmental factors can still lead to degradation over time.
Mechanical Wear: Components like bearings and gearboxes may experience wear due to continuous operation, necessitating regular maintenance and repla...
Inox wind turbine generators often face bearing failures due to various operational and environmental factors.
Lubrication Issues: Insufficient or contaminated lubrication can lead to increased friction and wear, causing premature bearing failure.
Misalignment: Improper alignment of the generator shaft can create uneven loads on the bearings, leading to damage over time.
Vibration: Excessive vibration from the turbine or ...
I applied via Naukri.com and was interviewed in Jun 2021. There was 1 interview round.
I applied via Approached by Company and was interviewed before Oct 2021. There were 2 interview rounds.
Assistant Manager
27
salaries
| ₹5 L/yr - ₹9.9 L/yr |
Deputy Manager
27
salaries
| ₹9.1 L/yr - ₹15 L/yr |
Maintenance Engineer
13
salaries
| ₹2.8 L/yr - ₹5 L/yr |
Assistant Engineer
11
salaries
| ₹2.8 L/yr - ₹4.2 L/yr |
Quality Engineer
10
salaries
| ₹1.8 L/yr - ₹4.5 L/yr |
UTL Solar
Danfoss Power Solutions
LM Wind Power
Senvion