Upload Button Icon Add office photos
Engaged Employer

i

This company page is being actively managed by ArcelorMittal Nippon Steel Team. If you also belong to the team, you can get access from here

ArcelorMittal Nippon Steel Verified Tick

Compare button icon Compare button icon Compare

Filter interviews by

ArcelorMittal Nippon Steel Electrical Engineer Interview Questions and Answers

Updated 6 Apr 2025

8 Interview questions

An Electrical Engineer was asked 4mo ago
Q. Which conductor is used in transmission lines?
Ans. 

Transmission lines typically use aluminum or copper conductors for efficient electricity transfer over long distances.

  • Aluminum conductors are lightweight and have good conductivity, making them ideal for overhead transmission lines.

  • Copper conductors offer higher conductivity than aluminum but are heavier and more expensive.

  • ACSR (Aluminum Conductor Steel Reinforced) combines aluminum and steel for strength and cond...

An Electrical Engineer was asked 4mo ago
Q. Explain the working principle of transformers.
Ans. 

Transformers operate on electromagnetic induction to transfer electrical energy between circuits at different voltage levels.

  • Transformers consist of two coils: primary and secondary.

  • They work on the principle of Faraday's law of electromagnetic induction.

  • When alternating current flows through the primary coil, it creates a magnetic field.

  • This magnetic field induces a voltage in the secondary coil.

  • Transformers can ...

Electrical Engineer Interview Questions Asked at Other Companies

Q1. What is the difference between Switchgear and Circuit Breakers?
Q2. What is ATS, transformer maintenance procedure, protection of tra ... read more
asked in Tata Steel
Q3. What are composite error and ratio error in a current transformer ... read more
Q4. 1. Power factor of transformer 2. types of DC machine 3. Working ... read more
Q5. How many types of transformers are there based on voltage transfe ... read more
An Electrical Engineer was asked
Q. What is DP in Siemens communication?
Ans. 

DP in Siemens communication stands for Distributed Peripherals.

  • DP is a communication protocol used by Siemens for connecting distributed peripherals to a central control system.

  • It allows for real-time data exchange between the peripherals and the control system.

  • DP is commonly used in industrial automation applications.

  • Examples of DP communication modules include DP/DP couplers and DP slaves.

An Electrical Engineer was asked
Q. Why is it important to improve the power factor?
Ans. 

Improving power factor helps in reducing energy losses, increasing system efficiency, and reducing electricity costs.

  • Improving power factor reduces the amount of reactive power flowing in the system, which in turn reduces energy losses.

  • Higher power factor means more efficient use of electricity and less strain on the electrical system.

  • Improving power factor can lead to reduced electricity costs for consumers and u...

An Electrical Engineer was asked
Q. How do we communicate between an S7 PLC and an ABB drive using Profibus?
Ans. 

To communicate S7 PLC and ABB drive using Profibus, you need to configure the Profibus network, set up the communication parameters, and establish the communication link.

  • Configure the Profibus network by setting the correct baud rate, address, and other network parameters.

  • Set up the communication parameters on both the S7 PLC and ABB drive to ensure they are compatible with each other.

  • Establish the communication l...

An Electrical Engineer was asked
Q. What is buccholz relay, how does it work?
Ans. 

Buccholz relay is a protective device used in oil-filled transformers to detect faults such as internal arcing or overheating.

  • Buccholz relay is installed in the oil pipe connecting the transformer tank and conservator tank.

  • It works based on the principle that gas is generated when a fault occurs in the transformer, causing oil level to drop and gas to accumulate in the relay.

  • The relay consists of two float switche...

ArcelorMittal Nippon Steel HR Interview Questions

44 questions and answers

Q. What motivates you?
Q. Are you able to work within a team?
Q. What are your 5-year goals with our company?
An Electrical Engineer was asked 4mo ago
Q. Motor working principle
Ans. 

Electric motors convert electrical energy into mechanical energy using electromagnetic principles.

  • Motors operate on the principle of electromagnetism, where a magnetic field interacts with current-carrying conductors.

  • The basic components include a stator (stationary part) and a rotor (rotating part).

  • In AC motors, alternating current creates a rotating magnetic field that induces motion in the rotor.

  • In DC motors, d...

Are these interview questions helpful?
An Electrical Engineer was asked 4mo ago
Q. Types of winding in motor
Ans. 

Motors utilize various winding types, including stator and rotor windings, to create magnetic fields for operation.

  • Stator Windings: Fixed windings that create a rotating magnetic field.

  • Rotor Windings: Located on the rotor, can be squirrel cage or wound type.

  • Lap Winding: Used in DC machines for low voltage and high current applications.

  • Wave Winding: Suitable for high voltage and low current applications.

  • Field Windi...

ArcelorMittal Nippon Steel Electrical Engineer Interview Experiences

7 interviews found

Interview experience
4
Good
Difficulty level
Moderate
Process Duration
Less than 2 weeks
Result
Not Selected

I applied via Recruitment Consulltant and was interviewed in Dec 2023. There was 1 interview round.

Round 1 - Technical 

(4 Questions)

  • Q1. Why do we improve power factor.
  • Ans. 

    Improving power factor helps in reducing energy losses, increasing system efficiency, and reducing electricity costs.

    • Improving power factor reduces the amount of reactive power flowing in the system, which in turn reduces energy losses.

    • Higher power factor means more efficient use of electricity and less strain on the electrical system.

    • Improving power factor can lead to reduced electricity costs for consumers and utilit...

  • Answered by AI
  • Q2. What is buccholz relay, how does it work?
  • Ans. 

    Buccholz relay is a protective device used in oil-filled transformers to detect faults such as internal arcing or overheating.

    • Buccholz relay is installed in the oil pipe connecting the transformer tank and conservator tank.

    • It works based on the principle that gas is generated when a fault occurs in the transformer, causing oil level to drop and gas to accumulate in the relay.

    • The relay consists of two float switches - o...

  • Answered by AI
  • Q3. What is DP in siemens communication?
  • Ans. 

    DP in Siemens communication stands for Distributed Peripherals.

    • DP is a communication protocol used by Siemens for connecting distributed peripherals to a central control system.

    • It allows for real-time data exchange between the peripherals and the control system.

    • DP is commonly used in industrial automation applications.

    • Examples of DP communication modules include DP/DP couplers and DP slaves.

  • Answered by AI
  • Q4. How do we communicate s7 PLC and abb drive using profibus.
  • Ans. 

    To communicate S7 PLC and ABB drive using Profibus, you need to configure the Profibus network, set up the communication parameters, and establish the communication link.

    • Configure the Profibus network by setting the correct baud rate, address, and other network parameters.

    • Set up the communication parameters on both the S7 PLC and ABB drive to ensure they are compatible with each other.

    • Establish the communication link b...

  • Answered by AI

Skills evaluated in this interview

Interview experience
3
Average
Difficulty level
-
Process Duration
-
Result
-
Round 1 - Aptitude Test 

Aptitude quite difficult and technical mcq round

Round 2 - Technical 

(2 Questions)

  • Q1. Simple question related electrical machine
  • Q2. Internship and project related question
Interview experience
4
Good
Difficulty level
Moderate
Process Duration
Less than 2 weeks
Result
Selected Selected

I appeared for an interview before Apr 2024, where I was asked the following questions.

  • Q1. Which conductor use in transmission line
  • Ans. 

    Transmission lines typically use aluminum or copper conductors for efficient electricity transfer over long distances.

    • Aluminum conductors are lightweight and have good conductivity, making them ideal for overhead transmission lines.

    • Copper conductors offer higher conductivity than aluminum but are heavier and more expensive.

    • ACSR (Aluminum Conductor Steel Reinforced) combines aluminum and steel for strength and conductiv...

  • Answered by AI
  • Q2. Motor working principle
  • Ans. 

    Electric motors convert electrical energy into mechanical energy using electromagnetic principles.

    • Motors operate on the principle of electromagnetism, where a magnetic field interacts with current-carrying conductors.

    • The basic components include a stator (stationary part) and a rotor (rotating part).

    • In AC motors, alternating current creates a rotating magnetic field that induces motion in the rotor.

    • In DC motors, direct...

  • Answered by AI
  • Q3. Types of winding in motor
  • Ans. 

    Motors utilize various winding types, including stator and rotor windings, to create magnetic fields for operation.

    • Stator Windings: Fixed windings that create a rotating magnetic field.

    • Rotor Windings: Located on the rotor, can be squirrel cage or wound type.

    • Lap Winding: Used in DC machines for low voltage and high current applications.

    • Wave Winding: Suitable for high voltage and low current applications.

    • Field Windings: ...

  • Answered by AI
  • Q4. Transformers working principle
  • Ans. 

    Transformers operate on electromagnetic induction to transfer electrical energy between circuits at different voltage levels.

    • Transformers consist of two coils: primary and secondary.

    • They work on the principle of Faraday's law of electromagnetic induction.

    • When alternating current flows through the primary coil, it creates a magnetic field.

    • This magnetic field induces a voltage in the secondary coil.

    • Transformers can step ...

  • Answered by AI

Interview Preparation Tips

Interview preparation tips for other job seekers - Don't join this company if you are a diploma holder kindly study further you get a good job in future.
Interview experience
3
Average
Difficulty level
Easy
Process Duration
Less than 2 weeks
Result
Selected Selected

I applied via Approached by Company and was interviewed in Jul 2022. There were 3 interview rounds.

Round 1 - Resume Shortlist 
Pro Tip by AmbitionBox:
Properly align and format text in your resume. A recruiter will have to spend more time reading poorly aligned text, leading to high chances of rejection.
View all tips
Round 2 - Technical 

(1 Question)

  • Q1. They will ask about transformer, NGR, power system protection?
Round 3 - HR 

(1 Question)

  • Q1. Ask about your location, salary expectation, relocation?

Interview Preparation Tips

Interview preparation tips for other job seekers - Be confident and stick to your knowledge. Don't be so confused and try to answer the question in short ams and to the point.
Interview experience
5
Excellent
Difficulty level
-
Process Duration
-
Result
-
Round 1 - Resume Shortlist 
Pro Tip by AmbitionBox:
Don’t add your photo or details such as gender, age, and address in your resume. These details do not add any value.
View all tips
Round 2 - Technical 

(2 Questions)

  • Q1. Transformer all details
  • Q2. Working of all Motor details

Interview Preparation Tips

Interview preparation tips for other job seekers - I have 12 year Experience Electrical & Instrumentation
Interview experience
4
Good
Difficulty level
Moderate
Process Duration
Less than 2 weeks
Result
Selected Selected

I applied via Referral and was interviewed before Jun 2022. There were 3 interview rounds.

Round 1 - Resume Shortlist 
Pro Tip by AmbitionBox:
Double-check your resume for any spelling mistakes. The recruiter may consider spelling mistakes as careless behavior or poor communication skills.
View all tips
Round 2 - Technical 

(1 Question)

  • Q1. Eot crane, transformer,VFD,motor
Round 3 - Technical 

(1 Question)

  • Q1. Electrical maintenance engineer field related

I applied via Campus Placement and was interviewed in May 2022. There were 3 interview rounds.

Round 1 - Resume Shortlist 
Pro Tip by AmbitionBox:
Keep your resume crisp and to the point. A recruiter looks at your resume for an average of 6 seconds, make sure to leave the best impression.
View all tips
Round 2 - Aptitude Test 

Reasoning and aptitude with technical

Round 3 - One-on-one 

(2 Questions)

  • Q1. Motor and transformer related questions
  • Q2. Tell me about yourself

Interview Preparation Tips

Interview preparation tips for other job seekers - Focus on induction motors concept and analysis part.

Top trending discussions

View All
Interview Hub
1w (edited)
anshitanegi
·
ex -
Planet Spark
When HR’s Chinese English made me drop the interview!
So, I talked to the HR yesterday about the interview. I asked Please send me the location But their English… bro I was shocked! It was like talking to someone jisne english nahi kuch ar hi seekh liya ho, if the HR’s English is this I can only imagine the rest of the company I decided to drop the interview with this chinese english😶‍🌫️
FeedCard Image
Got a question about ArcelorMittal Nippon Steel?
Ask anonymously on communities.

Interview questions from similar companies

Interview Questionnaire 

6 Questions

  • Q1. 1.what is composite error and ratio error in current transformer?
  • Ans. 

    Composite error and ratio error are two types of errors in current transformers.

    • Composite error is the combination of ratio error and phase angle error in a current transformer.

    • Ratio error is the difference between the actual turns ratio and the specified turns ratio of a current transformer.

    • Phase angle error is the angular difference between the primary and secondary currents of a current transformer.

    • Composite error a...

  • Answered by AI
  • Q2. 2.Draw ckt diagram of a.c drive.
  • Ans. 

    An AC drive circuit diagram controls the speed of an AC motor by varying the frequency and voltage of the power supplied to it.

    • An AC drive consists of a rectifier, DC link, inverter, and control circuitry.

    • The rectifier converts AC power to DC power, which is stored in the DC link.

    • The inverter converts the DC power back to AC power with variable frequency and voltage.

    • The control circuitry adjusts the frequency and volta...

  • Answered by AI
  • Q3. 3.Draw single line diagram of distribution system with proper secification.
  • Ans. 

    A single line diagram of a distribution system is required with proper specifications.

    • The diagram should show the flow of power from the source to the load

    • It should include all components such as transformers, switchgear, and cables

    • The specifications should include voltage levels, power ratings, and protection devices

    • The diagram should follow standard symbols and conventions

    • Example: A 11 kV distribution system with a 5...

  • Answered by AI
  • Q4. 4.Why do the dewpoint test in transformer?
  • Ans. 

    Dewpoint test is done in transformer to check the moisture content in the insulation oil.

    • Moisture in insulation oil can cause breakdown of transformer insulation

    • Dewpoint test helps to determine the moisture content in the oil

    • It is a preventive maintenance measure to avoid transformer failure

    • The test involves cooling a mirror until dew forms on it, and measuring the temperature at which dew forms

  • Answered by AI
  • Q5. 5.What is the difference between power transformer and distribution transformer?
  • Q6. 6.How to work Buchholz relay in transformer.
  • Ans. 

    Buchholz relay is used to protect transformers from faults by detecting gas and oil flow abnormalities.

    • Buchholz relay is installed in the pipe connecting the transformer tank and conservator tank.

    • It operates based on the principle that faults in the transformer generate gases and cause oil flow disturbances.

    • When gas or oil flow abnormalities occur, the relay trips and sends a signal to the control panel to isolate the ...

  • Answered by AI

Interview Preparation Tips

Round: Resume Shortlist
Experience: My resume was shortlisted from naukri.com.

I applied via Approached by Company and was interviewed before Sep 2021. There was 1 interview round.

Round 1 - Technical 

(2 Questions)

  • Q1. Electrical technical
  • Q2. Motor maintance, pull card ,zss,all light connection etc

Interview Preparation Tips

Interview preparation tips for other job seekers - Electrical technician working jindal Steel and Power Dongamauha

I applied via Naukri.com and was interviewed in Feb 2021. There were 4 interview rounds.

Interview Questionnaire 

1 Question

  • Q1. Tell me about your self ?about your work ,some basics question for you technical feild.

Interview Preparation Tips

Interview preparation tips for other job seekers - Always have positive attitude.be a good lisner ,calm and compose at that interview time because that it's show your personality to hw u are.

ArcelorMittal Nippon Steel Interview FAQs

How many rounds are there in ArcelorMittal Nippon Steel Electrical Engineer interview?
ArcelorMittal Nippon Steel interview process usually has 2-3 rounds. The most common rounds in the ArcelorMittal Nippon Steel interview process are Technical, Resume Shortlist and Aptitude Test.
What are the top questions asked in ArcelorMittal Nippon Steel Electrical Engineer interview?

Some of the top questions asked at the ArcelorMittal Nippon Steel Electrical Engineer interview -

  1. How do we communicate s7 PLC and abb drive using profib...read more
  2. What is buccholz relay, how does it wo...read more
  3. What is DP in siemens communicati...read more

Tell us how to improve this page.

Overall Interview Experience Rating

4.2/5

based on 9 interview experiences

Difficulty level

Easy 25%
Moderate 75%

Duration

Less than 2 weeks 100%
View more
ArcelorMittal Nippon Steel Electrical Engineer Salary
based on 164 salaries
₹2.2 L/yr - ₹6.6 L/yr
12% less than the average Electrical Engineer Salary in India
View more details

ArcelorMittal Nippon Steel Electrical Engineer Reviews and Ratings

based on 40 reviews

4.1/5

Rating in categories

4.0

Skill development

3.6

Work-life balance

3.7

Salary

4.3

Job security

3.6

Company culture

3.5

Promotions

3.4

Work satisfaction

Explore 40 Reviews and Ratings
Deputy Manager
806 salaries
unlock blur

₹8.2 L/yr - ₹15 L/yr

Assistant Manager
657 salaries
unlock blur

₹5 L/yr - ₹11.2 L/yr

Manager
588 salaries
unlock blur

₹10.9 L/yr - ₹19.3 L/yr

Assistant Field Engineer
430 salaries
unlock blur

₹1.9 L/yr - ₹5.2 L/yr

Engineer
388 salaries
unlock blur

₹3.5 L/yr - ₹8 L/yr

Explore more salaries
Compare ArcelorMittal Nippon Steel with

Tata Steel

4.0
Compare

JSW Steel

3.9
Compare

Jindal Steel and Power

3.9
Compare

Jindal Stainless

4.2
Compare
write
Share an Interview