Open secondary winding in potential transformer causes high voltage in secondary circuit.
Secondary voltage increases to dangerous levels
May cause insulation failure
Can damage equipment connected to secondary circuit
Can be prevented by using protective devices like fuses and circuit breakers
Top trending discussions
I appeared for an interview in Aug 2019.
I applied via Walk-in and was interviewed before Dec 2019. There were 4 interview rounds.
I applied via Walk-in and was interviewed before Aug 2020. There was 1 interview round.
I applied via Referral and was interviewed before Jun 2020. There were 5 interview rounds.
Developed a solution for optimizing a complex algorithm for a client in the finance industry
Client had a large dataset that needed to be processed quickly
Implemented parallel processing to speed up the algorithm
Optimized the code to reduce memory usage
Collaborated with the client to fine-tune the algorithm for their specific needs
I applied via Naukri.com and was interviewed in Oct 2021. There were 2 interview rounds.
They ask to many technical question and ask to code also
They ask for your background and thing you learnt in your past
I applied via Referral
Basics leetcode with optimization was asked
I appeared for an interview before Apr 2024, where I was asked the following questions.
The refrigeration cycle is a thermodynamic process that removes heat from a designated area to lower its temperature.
1. Evaporation: Refrigerant absorbs heat from the environment, turning from liquid to gas.
2. Compression: The gas is compressed, increasing its pressure and temperature.
3. Condensation: The hot gas releases heat to the surroundings, condensing back into a liquid.
4. Expansion: The liquid refrigerant expan...
Chillers and VRF systems differ in design, application, and efficiency, with various compressor types influencing performance.
Chillers are centralized cooling systems, while VRF systems are decentralized and allow for individual zone control.
Chillers typically use water or refrigerant to cool large buildings, e.g., centrifugal chillers for commercial use.
VRF systems use refrigerant as the cooling medium and can simulta...
COP measures efficiency in heating/cooling systems; heat load calculations determine required capacity for HVAC systems.
COP (Coefficient of Performance) is the ratio of useful heating or cooling provided to the energy consumed.
Heat load calculations assess the thermal energy needed to maintain desired indoor temperatures.
Types of PCBs (Printed Circuit Boards) in VRF (Variable Refrigerant Flow) systems include control P...
based on 1 review
Rating in categories
Assistant Manager
230
salaries
| ₹6.3 L/yr - ₹17.3 L/yr |
Sales Executive
205
salaries
| ₹1.5 L/yr - ₹6 L/yr |
Area Sales Manager
189
salaries
| ₹6.6 L/yr - ₹22 L/yr |
Deputy Manager
177
salaries
| ₹8.9 L/yr - ₹22.5 L/yr |
Senior Executive
111
salaries
| ₹3.7 L/yr - ₹12.5 L/yr |
vivo
OPPO
Dell
LG Electronics