Filter interviews by
Top trending discussions
posted on 3 May 2019
Seeking new challenges, growth opportunities, and a better work-life balance.
Looking for new challenges and opportunities for growth
Seeking a better work-life balance
Interested in working with a different team or on different projects
I applied via Naukri.com and was interviewed in Apr 2021. There were 3 interview rounds.
What is relay..who it's work what is conductor tell about plc,scada,hmi
My first project involved designing a PLC motor control system with a 5-second delay for operational efficiency.
Utilized a PLC (Programmable Logic Controller) to automate motor operations.
Implemented a 5-second delay to prevent motor overload during start-up.
Designed the logic using ladder diagrams for clear visualization.
Tested the system to ensure the delay function worked as intended.
Integrated safety features to pr...
I have worked on various DCS architectures in my career, including those for chemical plants and power plants.
Designed and implemented DCS architecture for a chemical plant project
Developed DCS architecture for a power plant project
Worked on DCS architecture for a water treatment plant project
Collaborated with team to create DCS architecture for a pharmaceutical plant project
A control valve is a device used to regulate the flow of a fluid in a system by varying the size of the flow passage.
Control valves are commonly used in industries such as oil and gas, chemical, and power plants.
They can be operated manually, pneumatically, electrically, or through a combination of these methods.
The operation of a control valve involves adjusting the position of the valve plug or disc to control the fl...
I applied via Naukri.com and was interviewed in Dec 2022. There were 2 interview rounds.
Industrial communication protocols are standards for data exchange between devices in industrial automation and control systems.
Some common industrial communication protocols include Modbus, Profibus, DeviceNet, Ethernet/IP, and CANopen.
These protocols enable devices from different manufacturers to communicate with each other and exchange data.
Industrial communication protocols can be wired or wireless, and can operate...
MODBUS settings include baud rate, parity, data bits, stop bits, and slave address.
Baud rate determines the speed of communication between devices.
Parity is used for error checking and can be set to even, odd, or none.
Data bits determine the number of bits used to represent each character.
Stop bits indicate the end of a character and can be set to 1 or 2.
Slave address is used to identify the device on the network.
Examp...
The maximum speed in Modbus depends on the baud rate and cable length.
Modbus speed is measured in baud rate
Higher baud rates allow for faster data transfer
Cable length can also affect the maximum speed
For example, at 9600 baud rate, the maximum cable length is 1200 meters
The number of devices that can be added in Modbus depends on the network architecture and the number of available addresses.
The maximum number of devices that can be added to a Modbus network is 247.
The number of available addresses depends on the type of Modbus protocol used (RTU or TCP/IP).
The network architecture also plays a role in determining the number of devices that can be added.
It is important to ensure that ...
Modbus communication types include RTU, ASCII, and TCP/IP.
RTU (Remote Terminal Unit) is a serial communication protocol that uses binary code to transmit data.
ASCII (American Standard Code for Information Interchange) is a serial communication protocol that uses ASCII characters to transmit data.
TCP/IP (Transmission Control Protocol/Internet Protocol) is a network communication protocol that uses Ethernet to transmit d...
The maximum input output handle refers to the maximum number of inputs and outputs that a device can handle.
The maximum input output handle varies depending on the device and its specifications.
It is important to consider the maximum input output handle when selecting a device for a project.
For example, a PLC may have a maximum input output handle of 256 inputs and 256 outputs.
Another example is a microcontroller with ...
The number of pages designed in HMI depends on the project requirements and complexity.
The number of pages can range from a few to hundreds depending on the project scope.
The complexity of the HMI design and functionality also affects the number of pages.
Factors such as user interface, data visualization, and system integration can impact the number of pages.
It is important to prioritize user experience and ease of nav...
Troubleshooting Profibus involves checking physical connections, network configuration, and device settings.
Check physical connections to ensure cables are properly connected and not damaged.
Verify network configuration settings such as baud rate, parity, and address assignments.
Inspect device settings to ensure they match the network configuration and are functioning correctly.
Use diagnostic tools like Profibus analyz...
based on 2 interview experiences
based on 19 reviews
Rating in categories
Team Lead
71
salaries
| ₹9.7 L/yr - ₹18 L/yr |
Senior Engineer
57
salaries
| ₹5.9 L/yr - ₹12.2 L/yr |
Design Engineer
47
salaries
| ₹3.1 L/yr - ₹7.2 L/yr |
Service Engineer
46
salaries
| ₹2.3 L/yr - ₹7 L/yr |
Assistant Manager
35
salaries
| ₹11.8 L/yr - ₹20.4 L/yr |
John Deere
Cummins
ABB
CNH ( Case New Holland)