Filter interviews by
Before, during, and after welding, various aspects are inspected to ensure quality and safety.
Before welding, the materials and equipment are inspected for cleanliness, proper setup, and suitability for the welding process.
During welding, the inspector checks for proper welding technique, adherence to welding procedures, and the quality of welds being produced.
After welding, the inspector inspects the completed we...
Fabrication spools must be inspected thoroughly before releasing to the erection site.
Check for any defects or damages on the spool.
Ensure that the spool meets the required specifications and standards.
Verify that all necessary documentation and certifications are in place.
Perform visual and dimensional inspections on the spool.
Conduct hydrostatic testing to check for leaks or other issues.
Ensure that the spool is...
I will check both Ground Inspection and IMIR for quality control purposes.
I will check the ground inspection report for any discrepancies or issues with the physical product.
I will also review the IMIR (In-Process Material Inspection Report) to ensure that all necessary inspections and tests have been completed.
I will verify that all required documentation is present and accurate.
I will communicate any issues or c...
During spool erection time, I will check for proper alignment, fit-up, welding quality, and dimensional accuracy.
Check for proper alignment of spool components
Ensure fit-up is correct and there are no gaps or misalignments
Inspect welding quality for defects such as cracks, porosity, and incomplete fusion
Verify dimensional accuracy of the spool according to the design specifications
Check for any damage or corrosion...
Hydro test procedures involve filling a vessel or pipeline with water and pressurizing it to check for leaks or structural integrity.
The vessel or pipeline is filled with water
The water is pressurized to a predetermined level
The pressure is held for a specified amount of time
The vessel or pipeline is inspected for leaks or structural damage
If no issues are found, the water is drained and the vessel or pipeline is ...
In RT film check, I will inspect for any defects or anomalies in the radiographic image. Sensitivity calculation is the measure of the smallest detectable flaw.
Inspect for any defects or anomalies in the radiographic image
Check for proper exposure and contrast
Ensure that the film is free from any artifacts or processing errors
Calculate the sensitivity of the film to detect the smallest flaw
Use a penetrameter to de...
I appeared for an interview before Feb 2024.
I applied via Referral and was interviewed in Jun 2021. There were 3 interview rounds.
Before, during, and after welding, various aspects are inspected to ensure quality and safety.
Before welding, the materials and equipment are inspected for cleanliness, proper setup, and suitability for the welding process.
During welding, the inspector checks for proper welding technique, adherence to welding procedures, and the quality of welds being produced.
After welding, the inspector inspects the completed welds f...
Fabrication spools must be inspected thoroughly before releasing to the erection site.
Check for any defects or damages on the spool.
Ensure that the spool meets the required specifications and standards.
Verify that all necessary documentation and certifications are in place.
Perform visual and dimensional inspections on the spool.
Conduct hydrostatic testing to check for leaks or other issues.
Ensure that the spool is prop...
I will check both Ground Inspection and IMIR for quality control purposes.
I will check the ground inspection report for any discrepancies or issues with the physical product.
I will also review the IMIR (In-Process Material Inspection Report) to ensure that all necessary inspections and tests have been completed.
I will verify that all required documentation is present and accurate.
I will communicate any issues or concer...
In RT film check, I will inspect for any defects or anomalies in the radiographic image. Sensitivity calculation is the measure of the smallest detectable flaw.
Inspect for any defects or anomalies in the radiographic image
Check for proper exposure and contrast
Ensure that the film is free from any artifacts or processing errors
Calculate the sensitivity of the film to detect the smallest flaw
Use a penetrameter to determi...
Hydro test procedures involve filling a vessel or pipeline with water and pressurizing it to check for leaks or structural integrity.
The vessel or pipeline is filled with water
The water is pressurized to a predetermined level
The pressure is held for a specified amount of time
The vessel or pipeline is inspected for leaks or structural damage
If no issues are found, the water is drained and the vessel or pipeline is deeme...
During spool erection time, I will check for proper alignment, fit-up, welding quality, and dimensional accuracy.
Check for proper alignment of spool components
Ensure fit-up is correct and there are no gaps or misalignments
Inspect welding quality for defects such as cracks, porosity, and incomplete fusion
Verify dimensional accuracy of the spool according to the design specifications
Check for any damage or corrosion on t...
Top trending discussions
Chemical formulas represent the types and numbers of atoms in a compound.
Water - H2O
Carbon dioxide - CO2
Sodium chloride - NaCl
Anode and cathode are electrodes used in electrochemical cells to facilitate the flow of electrons.
Anode is the electrode where oxidation occurs and electrons are lost.
Cathode is the electrode where reduction occurs and electrons are gained.
In a battery, the anode is the negative terminal and the cathode is the positive terminal.
In an electrolytic cell, the anode is the positive terminal and the cathode is the negative...
H2O and HCl exhibit different behaviors due to their chemical properties.
H2O is a polar molecule, while HCl is a polar covalent molecule.
H2O has a higher boiling point and melting point than HCl.
HCl is a strong acid, while H2O is a neutral molecule.
H2O can act as a solvent for many substances, while HCl is mainly used in chemical reactions.
H2O has a higher density than HCl.
I applied via Naukri.com and was interviewed before Apr 2023. There were 2 interview rounds.
I have worked with various material grades including metals, plastics, and composites, ensuring quality and compliance.
Metals: Worked with stainless steel (Grade 304, 316) for corrosion resistance in medical devices.
Plastics: Experienced with high-density polyethylene (HDPE) for chemical resistance in packaging.
Composites: Used carbon fiber reinforced polymers for lightweight structural applications in aerospace.
Concre...
Material specifications for piping, forgings, fittings, tubes, and fasteners for MS materials include ASTM standards and specific grades.
ASTM A53/A53M - Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless
ASTM A105/A105M - Standard Specification for Carbon Steel Forgings for Piping Applications
ASTM A234/A234M - Standard Specification for Piping Fittings of Wrought Carbon Steel ...
SS316L has lower carbon content than SS316, making it more corrosion resistant and suitable for welding applications.
SS316L has lower carbon content (0.03% max) compared to SS316 (0.08% max)
SS316L is more corrosion resistant due to the lower carbon content
SS316L is commonly used in welding applications where post-weld annealing is not possible
SS316 is more commonly used in applications where higher strength is required
Refer to ASME Section II Part A for remaining chemical composition of SA-516 Gr. 70 plates
Refer to ASME Section II Part A for detailed chemical composition
Check the material test report (MTR) for specific chemical composition
Consult with the manufacturer or supplier for any additional information
Questions related to Standard reference, codes, welding and inspection
I applied via Recruitment Consulltant and was interviewed in Dec 2022. There were 2 interview rounds.
I am a passionate engineer with a strong background in software development and a keen interest in innovative technologies.
Education: Bachelor's degree in Computer Engineering from XYZ University.
Experience: 3 years of experience in software development at ABC Corp, focusing on web applications.
Skills: Proficient in languages like Python, Java, and JavaScript; experienced in Agile methodologies.
Projects: Developed a pr...
I appeared for an interview in Feb 2025.
Some of the top questions asked at the Bureau Veritas QC Inspector interview -
based on 1 interview experience
Difficulty level
Duration
based on 4 reviews
Rating in categories
Surveyor
237
salaries
| ₹4.2 L/yr - ₹9.5 L/yr |
Chemist
187
salaries
| ₹1.8 L/yr - ₹5 L/yr |
Project Coordinator
172
salaries
| ₹2.5 L/yr - ₹7.5 L/yr |
Quality Inspector
167
salaries
| ₹3.2 L/yr - ₹7.1 L/yr |
Senior Surveyor
140
salaries
| ₹6.1 L/yr - ₹13.6 L/yr |
CMS Infosystems
Intertek
TÜV NORD
Medhaj Techno Concept