VBD test is conducted in transformers to ensure insulation integrity and detect any potential faults.
VBD test helps in identifying any weak spots in the insulation of the transformer
It helps in preventing breakdowns and ensuring the safety and reliability of the transformer
By conducting VBD test, any potential faults can be detected early and necessary maintenance can be carried out
It is a standard procedure in transfo...
Top trending discussions
Previous site infrastructure included data centers, networking equipment, servers, and storage systems.
Data centers were located in multiple regions for redundancy.
Networking equipment included routers, switches, and firewalls.
Servers were a mix of physical and virtual machines.
Storage systems used SAN and NAS technologies.
Backup and disaster recovery plans were in place.
Monitoring tools were used to track performance ...
Multiple scenarios of UPS DG CHILLER FAILURES
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
I appeared for an interview before Feb 2024.
I appeared for an interview in Jun 2025, where I was asked the following questions.
A breakdown voltage test assesses the insulation strength of electrical components by applying high voltage until failure occurs.
1. Prepare the test setup: Ensure all equipment is calibrated and safe for high voltage testing.
2. Select the component: Choose the electrical device or insulation material to be tested.
3. Apply voltage gradually: Increase the voltage slowly to avoid sudden breakdowns, monitoring the current.
...
The vector group test determines the phase relationship and connection type of transformers.
Identifies the phase displacement between primary and secondary windings.
Common vector groups include Yd11, Yy0, and Δy5.
Used to ensure compatibility in parallel operation of transformers.
Helps in understanding the neutral grounding and fault current paths.
The insulation resistance test measures the resistance of a transformer's insulation to ensure safety and performance.
Insulation resistance is measured in ohms, indicating the quality of insulation.
A common test voltage is 500V or 1000V DC, depending on the transformer rating.
A high IR value (typically > 1 MΩ) indicates good insulation; low values suggest potential insulation failure.
The test helps prevent electrica...
The turn ratio test measures the voltage transformation ratio of a transformer to ensure proper operation and efficiency.
It compares the primary and secondary winding turns of a transformer.
A typical turn ratio might be 10:1, meaning 10 turns on the primary for every 1 on the secondary.
The test helps identify issues like shorted turns or incorrect winding connections.
For example, if a transformer is rated for 240V/120V...
Phase-to-phase angle is the angle between two phases, while phase-to-neutral angle is the angle between a phase and neutral.
In a three-phase system, the phase-to-phase angle is typically 120 degrees apart.
For example, in a balanced three-phase system, the voltage between any two phases (e.g., A and B) is 120 degrees.
The phase-to-neutral angle is 0 degrees for the neutral phase and varies for other phases.
In a star conn...
I appeared for an interview in Aug 2023.
Electrical engineering involves the study and application of electricity, electronics, and electromagnetism in various technologies.
Designing electrical circuits for devices like smartphones and computers.
Developing power generation systems, such as solar panels and wind turbines.
Working on control systems for automation in manufacturing processes.
Creating communication systems, including satellite and wireless technol...
I applied via Naukri.com
I applied via Approached by Company and was interviewed in Apr 2022. There were 2 interview rounds.
CT and PT are used in electrical engineering for measurement and protection purposes.
CT (Current Transformer) is used to measure high currents and step them down to a level suitable for measurement instruments.
PT (Potential Transformer) is used to measure high voltages and step them down to a level suitable for measurement instruments.
CTs and PTs are also used for protection purposes, such as detecting faults and isola...
The number of transformer production varies depending on the company and market demand.
The number of transformer production is influenced by factors such as market demand, company size, and production capacity.
Large transformer manufacturers may produce thousands of transformers per year.
Smaller companies or custom transformer manufacturers may have lower production volumes.
The production volume can also vary based on ...
based on 1 interview experience
Difficulty level
Duration
based on 6 reviews
Rating in categories
Housekeeping Supervisor
75
salaries
| ₹1.4 L/yr - ₹3.5 L/yr |
Facility Executive
58
salaries
| ₹2.2 L/yr - ₹6.4 L/yr |
Operations Manager
33
salaries
| ₹4.4 L/yr - ₹10.4 L/yr |
Shift Engineer
27
salaries
| ₹2.7 L/yr - ₹4.6 L/yr |
Assistant Manager
21
salaries
| ₹4.8 L/yr - ₹9.5 L/yr |
Sodexo
Compass Group Support Services
ISS Facility Services
BVG India