Filter interviews by
The procedure for lighting up a boiler involves safety checks, fuel supply, ignition, and monitoring parameters.
1. Conduct safety checks: Ensure all safety devices are functional and the area is clear of hazards.
2. Prepare fuel supply: Verify that the fuel system is operational and the correct fuel type is available.
3. Purge the boiler: Remove any unburned fuel or gas from the combustion chamber to prevent explosi...
The rated voltage of a distribution transformer is the voltage at which it is designed to operate.
The rated voltage of a distribution transformer is typically specified by the manufacturer.
It is usually expressed in kilovolts (kV) or volts (V).
For example, a distribution transformer may have a rated voltage of 11 kV or 33 kV.
The rated voltage determines the maximum voltage that the transformer can handle without e...
Synchronous motors run on a constant speed.
Synchronous motors maintain a constant speed regardless of the load.
They are commonly used in applications that require precise speed control.
Examples of synchronous motors include those used in industrial machinery and electric clocks.
The type of motor used in cranes is typically an electric motor.
Electric motors are commonly used in cranes due to their efficiency and controllability.
AC induction motors and DC motors are the most common types used in cranes.
AC induction motors are preferred for their simplicity and reliability.
DC motors offer better speed control and are often used in more advanced crane systems.
Examples of crane motors include...
The frequency of AC supply varies depending on the country and region.
In North America, the frequency is typically 60 Hz.
In Europe and most other parts of the world, the frequency is typically 50 Hz.
The frequency can affect the performance of certain electrical devices.
Some countries have multiple frequency standards depending on the region.
Frequency can be measured using a frequency meter or multimeter.
The procedure for lighting up a boiler involves safety checks, fuel supply, ignition, and monitoring parameters.
1. Conduct safety checks: Ensure all safety devices are functional and the area is clear of hazards.
2. Prepare fuel supply: Verify that the fuel system is operational and the correct fuel type is available.
3. Purge the boiler: Remove any unburned fuel or gas from the combustion chamber to prevent explosions.
4...
Yes, I faced an emergency during a boiler shutdown that required immediate action to prevent a safety incident.
During a routine inspection, I noticed a pressure drop in the boiler system, indicating a potential leak.
I quickly initiated the emergency shutdown procedure to prevent any hazardous situations.
Coordinated with the maintenance team to isolate the affected section and conduct repairs.
Communicated with the contr...
I applied via Approached by Company and was interviewed in Oct 2024. There was 1 interview round.
I applied via LinkedIn and was interviewed in Feb 2023. There were 2 interview rounds.
I applied via Naukri.com and was interviewed before Oct 2022. There were 3 interview rounds.
Major modifications ,spares management, hypothetical question, time management during the work.
I applied via Referral and was interviewed before Dec 2022. There were 2 interview rounds.
I applied via Approached by Company and was interviewed before Oct 2023. There was 1 interview round.
The rated voltage of a distribution transformer is the voltage at which it is designed to operate.
The rated voltage of a distribution transformer is typically specified by the manufacturer.
It is usually expressed in kilovolts (kV) or volts (V).
For example, a distribution transformer may have a rated voltage of 11 kV or 33 kV.
The rated voltage determines the maximum voltage that the transformer can handle without exceed...
The type of motor used in cranes is typically an electric motor.
Electric motors are commonly used in cranes due to their efficiency and controllability.
AC induction motors and DC motors are the most common types used in cranes.
AC induction motors are preferred for their simplicity and reliability.
DC motors offer better speed control and are often used in more advanced crane systems.
Examples of crane motors include squi...
I appeared for an interview before May 2022.
I applied via Approached by Company and was interviewed before Nov 2022. There were 2 interview rounds.
I applied via Indeed and was interviewed before Jul 2020. There were 3 interview rounds.
Top trending discussions
The duration of Operational Energy Group India interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 12 interview experiences
Difficulty level
Duration
based on 223 reviews
Rating in categories
Bangalore / Bengaluru
3-8 Yrs
₹ 2.5-3.5 LPA
Electrical Engineer
43
salaries
| ₹2.2 L/yr - ₹5.8 L/yr |
Electrical Technician
21
salaries
| ₹2 L/yr - ₹4.3 L/yr |
Senior Engineer
19
salaries
| ₹4 L/yr - ₹7 L/yr |
Mechanical Engineer
16
salaries
| ₹2.5 L/yr - ₹5.8 L/yr |
Engineer
15
salaries
| ₹3.8 L/yr - ₹7.2 L/yr |
Dhoot Transmission
Doosan Power Systems
SAEL Industries Limited
LM Wind Power