i
Unichem
Laboratories
Filter interviews by
The least count of a vernier caliper is the smallest measurement that can be read on the scale.
The least count is determined by the number of divisions on the vernier scale and the main scale.
For example, if the main scale has divisions of 1 mm and the vernier scale has 10 divisions that match up with 9 divisions on the main scale, the least count would be 0.1 mm.
The least count is important for accurately measuring sm...
Sine bars are precision tools used in machining to measure angles accurately by utilizing trigonometric principles.
Sine bars consist of a flat bar with two precision-ground cylinders at each end.
They are used to set and measure angles by placing a workpiece on the bar.
The angle is calculated using the sine function, where the height of the workpiece is related to the length of the sine bar.
For example, a sine bar with ...
Top trending discussions
I appeared for an interview in May 2017.
posted on 19 Dec 2019
I applied via Referral and was interviewed before Dec 2018. There were 3 interview rounds.
The Ich limit for methanol is 0.6% and it is classified as a class 3 solvent.
The Ich limit for methanol refers to the maximum allowable amount of methanol in a pharmaceutical product.
The Ich limit for methanol is set at 0.6%, meaning that the concentration of methanol should not exceed 0.6% in the product.
Methanol is classified as a class 3 solvent according to the International Council for Harmonisation of Technical R...
The specification limit for known and unknown impurities varies depending on the specific substance being tested.
The specification limit for known impurities is typically set by regulatory agencies or pharmacopoeias.
For example, the United States Pharmacopeia (USP) sets limits for known impurities in pharmaceutical substances.
The specification limit for unknown impurities is usually determined through method validation...
I applied via Approached by Company and was interviewed before Jun 2021. There were 2 interview rounds.
I applied via Approached by Company and was interviewed in Jul 2023. There were 2 interview rounds.
I applied via LinkedIn and was interviewed in Aug 2023. There was 1 interview round.
Lyophilization is a technique used to remove water from a product by freeze-drying it.
Lyophilization involves freezing the product and then subjecting it to a vacuum to remove the frozen water through sublimation.
This technique is commonly used in the pharmaceutical industry to preserve drugs and vaccines.
Lyophilization helps to extend the shelf life of products and maintain their stability.
It is also used in the food ...
Trouble shooting during cycle development
Identify the problem or issue
Analyze the root cause
Develop a plan to resolve the problem
Implement the plan
Monitor and evaluate the results
Make necessary adjustments if needed
Implementing CAPA involves identifying issues, taking corrective actions, and monitoring their effectiveness for continuous improvement.
Identify the root cause of the issue using tools like Fishbone diagrams or 5 Whys.
Develop a corrective action plan that outlines specific actions to address the root cause.
Implement the corrective actions and ensure all stakeholders are informed and trained as necessary.
Establish metri...
Effectiveness monitoring should be conducted regularly to ensure goals are met and improvements are identified promptly.
Conduct monthly reviews to assess progress against key performance indicators (KPIs).
Implement quarterly surveys to gather feedback from stakeholders on effectiveness.
Utilize bi-annual audits to evaluate processes and outcomes.
Example: A marketing team may analyze campaign performance every two weeks ...
The extension process of QMS documents ensures compliance, updates, and effective communication within an organization.
Identify the need for extension: Regularly review QMS documents to determine if updates are necessary due to changes in regulations or processes.
Gather input from stakeholders: Involve relevant departments to provide feedback on the current documents and suggest improvements.
Draft the revised document:...
Our quality system allows for a defined number of extensions based on specific criteria and regulatory requirements.
Extensions are typically allowed for unforeseen circumstances, such as supply chain disruptions.
For example, if a critical component is delayed, an extension may be granted to ensure quality standards are met.
Extensions must be documented and justified to maintain compliance with quality assurance protoco...
Trends are prepared by analyzing data over time, with frequency determined by the nature of the data and reporting needs.
Identify key metrics to track, such as sales growth or patient outcomes.
Collect data regularly, e.g., weekly sales reports or monthly patient feedback.
Use tools like Excel or BI software for data visualization.
Analyze historical data to establish baseline trends.
Adjust frequency based on the volatili...
I analyze data, identify patterns, and use statistical tools to prepare and forecast trends effectively.
Collect relevant data from various sources, such as sales reports and market research.
Use statistical software (e.g., Excel, R) to analyze data and identify patterns.
Visualize trends using graphs and charts for better understanding.
Monitor industry news and reports to stay updated on market changes.
Example: Analyzing...
posted on 14 Mar 2024
I applied via Naukri.com and was interviewed before Mar 2023. There was 1 interview round.
The type of level sensor commonly used in fermenters is a capacitance level sensor.
Capacitance level sensor is commonly used in fermenters to measure the level of liquid or solid materials.
This type of sensor works by detecting changes in capacitance as the level of the material changes.
Capacitance level sensors are accurate, reliable, and suitable for various types of fermenters.
Other types of level sensors used in fe...
Officer
521
salaries
| ₹1.8 L/yr - ₹5.9 L/yr |
Senior Officer
295
salaries
| ₹2.8 L/yr - ₹7 L/yr |
Executive
219
salaries
| ₹4.2 L/yr - ₹10 L/yr |
Research Associate
187
salaries
| ₹2 L/yr - ₹6.2 L/yr |
Assistant Manager
159
salaries
| ₹6.2 L/yr - ₹16.1 L/yr |
Hetero
Abbott
Micro Labs
Ajanta Pharma