i
Unison
Pharmaceuticals
Filter interviews by
I appeared for an interview before Jul 2024, where I was asked the following questions.
Top trending discussions
I applied via Walk-in and was interviewed in Dec 2019. There was 1 interview round.
I applied via Recruitment Consultant and was interviewed in Feb 2020. There was 1 interview round.
VCB stands for Vacuum Circuit Breaker, which is an electrical switch that uses vacuum as the dielectric medium.
VCB is used to protect electrical equipment from damage caused by overcurrents and short circuits.
It is commonly used in high voltage power systems.
VCBs are more reliable and require less maintenance compared to other types of circuit breakers.
They are also more environmentally friendly as they do not use any ...
DG stands for Diesel Generator, which is a backup power source used in case of power outages.
DG is a standalone power source that runs on diesel fuel.
It is commonly used as a backup power source in case of power outages.
DGs are often used in hospitals, data centers, and other critical facilities to ensure uninterrupted power supply.
They come in various sizes and capacities, depending on the power requirements of the fa...
PLC stands for Programmable Logic Controller, a digital computer used for automation of electromechanical processes.
PLCs are used in industrial automation to control machinery and processes
They are programmed using ladder logic or other programming languages
PLCs can communicate with other devices and systems through various communication protocols
Examples of PLC applications include manufacturing, transportation, and b...
posted on 9 Apr 2021
I applied via Recruitment Consultant and was interviewed before Apr 2020. There were 4 interview rounds.
Air flow in HVAC ducting can be calculated using the formula Q = AV
Q = air flow rate in cubic feet per minute (CFM)
A = cross-sectional area of the duct in square feet
V = air velocity in feet per minute (FPM)
Air velocity can be measured using a pitot tube or an anemometer
Duct sizing and layout can affect air flow and should be considered in calculations
A reactor can be installed by following a few steps.
Choose a suitable location for the reactor
Prepare the foundation for the reactor
Install the reactor vessel and associated equipment
Connect the piping and electrical systems
Test the reactor for proper functioning
Commissioning of a reactor involves a series of tests and procedures to ensure safe and efficient operation.
Pre-commissioning checks and inspections
Functional testing of equipment and systems
Testing of safety systems
Fuel loading and reactor startup
Performance testing and optimization
Final acceptance testing
Documentation and training
Regulatory approval
Examples: Pressurized Water Reactor (PWR), Boiling Water Reactor (BWR...
Condensers are used to convert high-pressure vapor into liquid form.
Condensers are used in various industries such as power plants, refrigeration systems, and chemical processing plants.
They help in increasing the efficiency of the system by reducing the pressure and temperature of the vapor.
They also help in recovering valuable materials from the vapor, such as water in a power plant.
Examples of condensers include she...
I applied via Company Website and was interviewed in Oct 2023. There was 1 interview round.
I applied via Recruitment Consulltant and was interviewed before May 2023. There were 2 interview rounds.
I have strong skills in troubleshooting technical issues, analyzing data, and implementing solutions.
Proficient in using various technical tools and software
Strong problem-solving skills
Ability to work well under pressure and meet deadlines
Experience in conducting research and testing to identify issues
Excellent communication skills to explain technical concepts to non-technical individuals
Troubleshooting a cartonator involves diagnosing issues in packaging machinery to ensure efficient operation.
Check for jams: Inspect the feed area for any obstructions that may be causing the cartonator to stop.
Monitor settings: Ensure that the machine settings match the specifications for the cartons being used.
Inspect sensors: Verify that all sensors are functioning correctly, as faulty sensors can lead to misalignme...
Behevior is verry wrost
based on 1 interview experience
Difficulty level
Duration
Senior Executive
93
salaries
| ₹6.4 L/yr - ₹13.5 L/yr |
Senior Officer
88
salaries
| ₹3.4 L/yr - ₹6.3 L/yr |
Executive
85
salaries
| ₹4.4 L/yr - ₹8.8 L/yr |
Assistant Manager
58
salaries
| ₹8.7 L/yr - ₹14.5 L/yr |
Officer
53
salaries
| ₹2.4 L/yr - ₹5 L/yr |
Hetero
Abbott
Micro Labs
GlaxoSmithKline Pharmaceuticals