i
Alstom
Transportation
Filter interviews by
The checking mechanism for residual leakage current involves using a ground fault circuit interrupter (GFCI) or a leakage current tester.
A GFCI can detect and interrupt leakage current by comparing the amount of current flowing into and out of a circuit.
A leakage current tester measures the amount of current flowing through a circuit and compares it to a predetermined threshold.
Regular testing and maintenance of e...
Meggar process is a method used to measure the insulation resistance of electrical equipment.
Meggar process involves applying a high voltage DC current to the equipment and measuring the resulting insulation resistance.
It is commonly used in the maintenance and testing of electrical equipment to ensure safety and reliability.
The results of the meggar process can indicate if there are any faults or defects in the i...
After LOTO or isolation of electrical energy, a mechanism must be used to check whether electrical energy isolation has been done or not.
Visual inspection of the equipment to ensure that it is not energized
Use of a voltage tester to check for the presence of electrical energy
Verification of the LOTO or isolation tag
Testing the equipment to ensure that it is not operational
Communication with other workers to ensure...
Height work equipment includes ladders, scaffolds, aerial lifts, and fall protection systems.
Ladders: used for low height work
Scaffolds: used for medium height work
Aerial lifts: used for high height work
Fall protection systems: used to prevent falls from height
Examples: extension ladders, rolling scaffolds, scissor lifts, harnesses, guardrails
Various material lifting equipment are used in warehouses depending on the type of material and its weight.
Forklifts are commonly used for heavy loads
Pallet jacks are used for moving pallets
Hand trucks are used for smaller loads
Conveyor belts are used for continuous movement of materials
Hoists and cranes are used for lifting heavy equipment
Scissor lifts are used for lifting workers to higher levels
Loading dock lev...
Legal compliance for mechanical materials lifting equipment include OSHA regulations, ANSI standards, and manufacturer guidelines.
OSHA regulations require regular inspections and maintenance of lifting equipment.
ANSI standards provide guidelines for the design, construction, and testing of lifting equipment.
Manufacturer guidelines must be followed for proper use and maintenance of specific equipment.
Compliance wit...
Load center is the point where the weight of the load is concentrated during lifting operation.
It is the point where the weight of the load is concentrated
It is important to know the load center to ensure safe lifting operation
The load center varies depending on the shape and size of the load
Incorrect load center calculation can lead to accidents and injuries
Load lifting capacity decreases as radius increases.
The load lifting capacity is inversely proportional to the radius.
As the radius increases, the load lifting capacity decreases.
This is because the load moment arm increases with radius, making it harder to lift the load.
For example, a crane with a longer boom has a lower load lifting capacity than a crane with a shorter boom.
Fire NOC & CTO compliance is done by the local fire department and pollution control board respectively.
Fire NOC compliance is done by the local fire department.
CTO compliance is done by the pollution control board.
Both compliances are mandatory for any organization to operate.
The process involves inspection of the premises and ensuring all safety measures are in place.
Non-compliance can result in penalties and ev...
The fire water tank capacity is 50,000 gallons.
The fire water tank is used for emergency firefighting purposes.
It is important to regularly check and maintain the tank to ensure it is always ready for use.
The capacity of the tank may vary depending on the size and needs of the facility.
For example, a smaller facility may have a fire water tank with a capacity of 10,000 gallons.
On the other hand, a larger facility ...
I applied via Naukri.com and was interviewed in Sep 2022. There were 2 interview rounds.
Fire NOC conditions are the set of requirements that a building or establishment must meet to obtain a No Objection Certificate for fire safety.
Fire NOC conditions include having adequate fire exits, fire alarms, fire extinguishers, and sprinkler systems.
The building must also have clear access for fire trucks and emergency personnel.
Regular fire drills and safety training for employees are also required.
Examples of Fi...
Fire NOC & CTO compliance is done by the local fire department and pollution control board respectively.
Fire NOC compliance is done by the local fire department.
CTO compliance is done by the pollution control board.
Both compliances are mandatory for any organization to operate.
The process involves inspection of the premises and ensuring all safety measures are in place.
Non-compliance can result in penalties and even cl...
The fire water tank capacity is 50,000 gallons.
The fire water tank is used for emergency firefighting purposes.
It is important to regularly check and maintain the tank to ensure it is always ready for use.
The capacity of the tank may vary depending on the size and needs of the facility.
For example, a smaller facility may have a fire water tank with a capacity of 10,000 gallons.
On the other hand, a larger facility may h...
Fire extinguisher requirements vary based on the hazard level of the workplace.
Light hazard workplaces require water, foam, or dry powder extinguishers.
Ordinary hazard workplaces require water, foam, dry powder, or carbon dioxide extinguishers.
High hazard workplaces require foam, dry powder, carbon dioxide, or specialized extinguishers such as halon or clean agent.
The specific requirements may vary by country and indus...
Fire extinguishers should be placed at a height of 3.5 to 5 feet from the floor.
The ideal height for fire extinguishers is between 3.5 to 5 feet from the floor.
This ensures that the extinguisher is easily accessible in case of a fire.
The height should be adjusted based on the height of the ceiling and the size of the room.
Extinguishers should be mounted on brackets or in cabinets to prevent them from falling.
It is impo...
Construction hazards include falls, electrical hazards, noise, and exposure to hazardous materials.
Falls from heights or on slippery surfaces
Electrical hazards from exposed wires or faulty equipment
Noise exposure from heavy machinery and equipment
Exposure to hazardous materials such as asbestos, lead, and silica dust
Risk of fires and explosions from flammable materials and chemicals
Physical strain and injuries from lif...
Height work equipment includes ladders, scaffolds, aerial lifts, and fall protection systems.
Ladders: used for low height work
Scaffolds: used for medium height work
Aerial lifts: used for high height work
Fall protection systems: used to prevent falls from height
Examples: extension ladders, rolling scaffolds, scissor lifts, harnesses, guardrails
Lifting safety requirements include proper technique, use of equipment, and weight limits.
Use proper lifting technique, such as bending at the knees and keeping the back straight
Use equipment such as lifting belts, back braces, and lifting straps when necessary
Know weight limits and do not exceed them
Ensure clear pathways and good visibility when moving heavy objects
Train employees on proper lifting techniques and safe...
Various material lifting equipment are used in warehouses depending on the type of material and its weight.
Forklifts are commonly used for heavy loads
Pallet jacks are used for moving pallets
Hand trucks are used for smaller loads
Conveyor belts are used for continuous movement of materials
Hoists and cranes are used for lifting heavy equipment
Scissor lifts are used for lifting workers to higher levels
Loading dock levelers...
Legal compliance for mechanical materials lifting equipment include OSHA regulations, ANSI standards, and manufacturer guidelines.
OSHA regulations require regular inspections and maintenance of lifting equipment.
ANSI standards provide guidelines for the design, construction, and testing of lifting equipment.
Manufacturer guidelines must be followed for proper use and maintenance of specific equipment.
Compliance with the...
Load center is the point where the weight of the load is concentrated during lifting operation.
It is the point where the weight of the load is concentrated
It is important to know the load center to ensure safe lifting operation
The load center varies depending on the shape and size of the load
Incorrect load center calculation can lead to accidents and injuries
Load lifting capacity decreases as radius increases.
The load lifting capacity is inversely proportional to the radius.
As the radius increases, the load lifting capacity decreases.
This is because the load moment arm increases with radius, making it harder to lift the load.
For example, a crane with a longer boom has a lower load lifting capacity than a crane with a shorter boom.
The checking mechanism for residual leakage current involves using a ground fault circuit interrupter (GFCI) or a leakage current tester.
A GFCI can detect and interrupt leakage current by comparing the amount of current flowing into and out of a circuit.
A leakage current tester measures the amount of current flowing through a circuit and compares it to a predetermined threshold.
Regular testing and maintenance of electr...
Meggar process is a method used to measure the insulation resistance of electrical equipment.
Meggar process involves applying a high voltage DC current to the equipment and measuring the resulting insulation resistance.
It is commonly used in the maintenance and testing of electrical equipment to ensure safety and reliability.
The results of the meggar process can indicate if there are any faults or defects in the insula...
After LOTO or isolation of electrical energy, a mechanism must be used to check whether electrical energy isolation has been done or not.
Visual inspection of the equipment to ensure that it is not energized
Use of a voltage tester to check for the presence of electrical energy
Verification of the LOTO or isolation tag
Testing the equipment to ensure that it is not operational
Communication with other workers to ensure that...
I am committed to the organization's mission and values and see a long-term future here.
I have researched the company and believe in its goals and values
I am looking for stability and growth opportunities
I am willing to invest time and effort in developing my skills and contributing to the company's success
I am open to discussing career advancement and growth opportunities with my manager
Top trending discussions
posted on 11 May 2018
posted on 2 Mar 2021
I appeared for an interview before Mar 2020.
posted on 18 Jan 2020
I applied via Naukri.com and was interviewed in Jul 2019. There were 3 interview rounds.
Maintain elevation of underground piping by using level instruments and proper installation techniques.
Use a level instrument to check the elevation of the piping during installation.
Ensure that the piping is installed with a consistent slope to prevent low spots where water can accumulate.
Regularly inspect the piping to ensure that it has not shifted or settled, which can affect the elevation.
Consider using supports o...
Welding electrodes are chosen based on the material being welded. Different materials require different types of electrodes.
Electrodes for mild steel have a coating that produces a stable arc and minimal spatter.
Stainless steel electrodes have a coating that resists corrosion and produces a smooth, clean weld.
Cast iron electrodes have a high nickel content to prevent cracking.
Aluminum electrodes have a special coating ...
posted on 12 Jul 2022
I applied via Campus Placement and was interviewed before Jul 2021. There were 2 interview rounds.
Computer aptitude test
posted on 12 Oct 2020
I applied via Naukri.com and was interviewed before Oct 2019. There were 3 interview rounds.
posted on 14 Feb 2021
posted on 2 May 2021
posted on 4 Mar 2022
I applied via Approached by Company and was interviewed before Mar 2021. There was 1 interview round.
posted on 27 Apr 2022
I applied via Referral and was interviewed before Apr 2021. There were 2 interview rounds.
Some of the top questions asked at the Alstom Transportation Environmental Health and Safety Lead interview -
based on 1 review
Rating in categories
Software Designer
501
salaries
| ₹5.9 L/yr - ₹21.7 L/yr |
System Engineer
201
salaries
| ₹8.4 L/yr - ₹19.1 L/yr |
Software Engineer
192
salaries
| ₹5.8 L/yr - ₹13.6 L/yr |
Senior Software Engineer
192
salaries
| ₹11.9 L/yr - ₹20 L/yr |
Team Lead
185
salaries
| ₹9.6 L/yr - ₹17.1 L/yr |
Larsen & Toubro Limited
Megha Engineering & Infrastructures
Shapoorji Pallonji Group
Tata Technologies