Filter interviews by
Image processing involves manipulating images to enhance, analyze, or extract information from them using algorithms and techniques.
Enhancement: Improving image quality, e.g., adjusting brightness and contrast.
Filtering: Removing noise or unwanted elements, e.g., using Gaussian filters.
Segmentation: Dividing an image into regions for analysis, e.g., identifying tumors in medical images.
Feature extraction: Identifying k...
Top trending discussions
posted on 5 May 2019
posted on 8 Mar 2021
I applied via Campus Placement and was interviewed before Mar 2020. There were 3 interview rounds.
posted on 17 Jan 2022
I applied via Recruitment Consultant and was interviewed before Jan 2021. There was 1 interview round.
I appeared for an interview before Apr 2024, where I was asked the following questions.
I applied via LinkedIn and was interviewed in Sep 2022. There were 2 interview rounds.
Questions related to applications engineering including tolerance stack up, bearing preloading, material selection, force calculation, and costing.
Tolerance stack up refers to the accumulation of variations in dimensions and tolerances of individual parts in an assembly.
Bearing preloading is the application of a small amount of force to the bearing to remove any internal clearance and improve its stiffness.
The choice b...
posted on 28 Jun 2022
I applied via Company Website and was interviewed in Oct 2021. There were 4 interview rounds.
posted on 19 May 2022
posted on 18 Feb 2025
I appeared for an interview before Feb 2024.
posted on 24 Apr 2024
I applied via Monster and was interviewed in Mar 2024. There were 2 interview rounds.
The number of systems that can be connected in a BACnet MSTP protocol network depends on factors like network speed, device types, and network topology.
The maximum number of devices that can be connected in a BACnet MSTP network is typically limited to 127 devices.
The actual number of systems that can be connected may vary based on the network speed and the types of devices being used.
Factors like network topology, cab...
Safety interlock for AHU ensures safe operation by preventing access during operation.
Safety interlock can be implemented using door switches to prevent access when AHU is running
Emergency stop buttons can be installed to immediately shut down AHU in case of emergency
Interlocks can be connected to the control system to automatically stop AHU if safety conditions are not met
based on 1 interview experience
based on 4 reviews
Rating in categories
Project Engineer
279
salaries
| ₹1.5 L/yr - ₹7 L/yr |
System Engineer
90
salaries
| ₹2.2 L/yr - ₹7.5 L/yr |
Senior Project Engineer
77
salaries
| ₹3 L/yr - ₹11 L/yr |
Design Engineer
64
salaries
| ₹1.8 L/yr - ₹5 L/yr |
Electrical Design Engineer
46
salaries
| ₹2.4 L/yr - ₹7.7 L/yr |
Schneider Electric
Johnson Controls
Honeywell Automation
Rockwell Automation