i
Dorset
Industries
Filter interviews by
I applied via Approached by Company and was interviewed before Sep 2023. There were 2 interview rounds.
I have had instances of shorter job tenures due to seeking growth opportunities. I applied at Dorset Industries for its reputation and growth potential.
I left my previous job after 2 years to pursue a higher position in a different company.
I left another job after 1 year due to lack of growth opportunities and challenges.
I applied at Dorset Industries because of its strong reputation in the industry and the potential f...
Discussing challenges in hiring and employer branding in the building material industry.
Challenge of hiring skilled labor: Implementing targeted recruitment strategies to attract specialized talent.
Team handling experience: Leading a diverse team through a project, ensuring effective communication and collaboration.
Best practices in employer branding: Utilizing social media campaigns to showcase company culture and emp...
Top trending discussions
I applied via Recruitment Consulltant and was interviewed before Sep 2021. There was 1 interview round.
I applied via Naukri.com and was interviewed in Jan 2021. There were 3 interview rounds.
I applied via Recruitment Consultant and was interviewed in Dec 2019. There were 3 interview rounds.
In this role, I will face challenges like team management, strategic planning, and adapting to industry changes.
Team Management: Balancing diverse team dynamics while ensuring productivity and morale.
Strategic Planning: Developing long-term goals and adapting strategies based on market trends.
Regulatory Compliance: Staying updated with industry regulations and ensuring adherence.
Resource Allocation: Efficiently managin...
I applied via Naukri.com and was interviewed in Sep 2021. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Jan 2021. There were 3 interview rounds.
4 wire and 2 wire are types of electrical wiring used for different purposes.
4 wire is used for three-phase power distribution while 2 wire is used for single-phase power distribution.
4 wire has four conductors - three phase conductors and one neutral conductor, while 2 wire has two conductors - one live and one neutral.
4 wire is used in industrial and commercial settings while 2 wire is used in residential settings.
4 ...
A fail-safe circuit is a safety mechanism that ensures a system will shut down in the event of a failure or malfunction.
Fail-safe circuits are commonly used in industries such as aviation, automotive, and nuclear power.
They are designed to prevent accidents or damage to equipment by shutting down the system if a fault is detected.
Examples of fail-safe circuits include emergency brakes in cars and automatic shutdown sys...
To detect the source of a fault, a systematic approach is required.
Start by identifying the symptoms of the fault
Trace the steps leading up to the fault
Use diagnostic tools to pinpoint the source of the fault
Check for any related issues that may have caused the fault
Document the findings for future reference
The rating of HT panel depends on its voltage and current capacity.
HT panel rating is determined by its voltage and current capacity
It can range from 11kV to 33kV or higher
The current capacity can range from a few hundred amps to several thousand amps
The rating is usually mentioned on the panel itself or in the technical specifications
It is important to ensure that the panel rating is suitable for the intended applicat...
Thermocouple temp is transmitted to DCS through analog signals or digital communication protocols.
Thermocouple generates a voltage signal proportional to temperature
This signal is amplified and transmitted to DCS through analog signals or digital communication protocols like HART, Modbus, etc.
Analog signals are converted to digital signals using analog-to-digital converters (ADC)
The DCS receives the signal and displays...
Signals of pump can be connected to DCS through analog or digital inputs.
Analog inputs can be used to measure the pump's flow rate, pressure, and temperature.
Digital inputs can be used to monitor the pump's status, such as on/off or fault conditions.
The signals can be wired directly to the DCS or through a remote I/O module.
Proper grounding and shielding techniques should be followed to avoid interference and noise.
Exa...
Silica transmitter measures the level of silica in water by using a colorimetric method.
Silica reacts with molybdate ions in an acidic solution to form a yellow complex.
The intensity of the yellow color is proportional to the amount of silica present.
The color is measured by a photometer and converted into a digital signal.
The signal is then transmitted to a control system for monitoring and control purposes.
I applied via Naukri.com and was interviewed in Apr 2021. There were 4 interview rounds.
I applied via Recruitment Consulltant and was interviewed in Oct 2022. There were 3 interview rounds.
I applied via AmbitionBox and was interviewed in Nov 2023. There was 1 interview round.
I applied via Recruitment Consultant and was interviewed in Dec 2021. There were 3 interview rounds.
based on 1 interview experience
Difficulty level
Duration
Assistant Area Manager
51
salaries
| ₹4.7 L/yr - ₹9.5 L/yr |
Sales Officer
39
salaries
| ₹3.1 L/yr - ₹5.7 L/yr |
Senior Sales Officer
33
salaries
| ₹4 L/yr - ₹6.7 L/yr |
Senior Officer
27
salaries
| ₹4.5 L/yr - ₹6.8 L/yr |
Officer
22
salaries
| ₹3.6 L/yr - ₹5.5 L/yr |
JK Cement
ACC
Ambuja Cements
Nuvoco Vistas