Filter interviews by
Bukolze relays are used in electrical engineering for their high reliability and ability to handle high voltage and current.
Bukolze relays are known for their robustness and durability.
They are commonly used in power distribution systems and industrial applications.
These relays can handle high voltage and current levels, making them suitable for heavy-duty operations.
They provide reliable switching and protection ...
Explosion vent in transformer is used for safety purposes.
It helps to release pressure build-up inside the transformer due to internal faults or external factors.
It prevents the transformer from exploding and causing damage to the surrounding area.
The vent is designed to open at a specific pressure level to ensure safe release of gases.
It is a mandatory safety feature in transformers as per industry standards.
Exam...
Ten delta test is used to detect winding deformation and shorted turns in transformer.
Detects winding deformation and shorted turns
Helps in identifying internal faults
Used for routine maintenance and troubleshooting
Star delta is used in electrical engineering to reduce starting current and protect motors.
Star delta connection is used for induction motors.
It reduces the starting current by a factor of √3.
It helps in reducing voltage drop during motor starting.
It protects the motor from excessive current and overheating.
It is commonly used in applications where the motor needs to start with a low current.
Star delta starter is used to reduce the starting current of induction motors.
Reduces the starting current of induction motors
Prevents excessive voltage drop in the power supply
Protects the motor windings from overheating
Allows for smooth and controlled motor starting
Commonly used in applications where high starting torque is not required
UV coil is a component used in HVAC systems to disinfect air by emitting ultraviolet light.
UV coil is installed in the air handling unit of HVAC systems.
It emits ultraviolet light to kill or deactivate microorganisms like bacteria, viruses, and mold spores.
UV light damages the DNA and RNA of these microorganisms, preventing them from reproducing.
UV coil helps improve indoor air quality by reducing the presence of ...
The OLTC (On-Load Tap Changer) in a transformer is typically connected to the high voltage side.
OLTC is connected to the high voltage winding of the transformer
It allows for tap changing while the transformer is energized
The low voltage side remains fixed while the high voltage side can be adjusted
Yes, OLTC is always connected in the HT voltage side.
OLTC stands for On-Load Tap Changer.
It is a device used in electrical power transformers to regulate the voltage level.
OLTC is typically connected on the high voltage (HT) side of the transformer.
It allows for tap changing while the transformer is energized and under load.
By changing the tap position, the OLTC can adjust the transformer's output voltage.
This hel...
UV Coil provides protection against over voltage and under voltage.
UV Coil is a device used in electrical systems to protect against voltage fluctuations.
It monitors the voltage levels and activates when the voltage exceeds or falls below the specified limits.
When the voltage exceeds the upper limit, the UV Coil disconnects the power supply to prevent damage to the equipment.
Similarly, when the voltage falls below...
I applied via Company Website
Bukolze relay is inter foult protection
Star delta is used in electrical engineering to reduce starting current and protect motors.
Star delta connection is used for induction motors.
It reduces the starting current by a factor of √3.
It helps in reducing voltage drop during motor starting.
It protects the motor from excessive current and overheating.
It is commonly used in applications where the motor needs to start with a low current.
Ten delta test is used to detect winding deformation and shorted turns in transformer.
Detects winding deformation and shorted turns
Helps in identifying internal faults
Used for routine maintenance and troubleshooting
I applied via Walk-in and was interviewed in Nov 2021. There were 2 interview rounds.
Star delta starter is used to reduce the starting current of induction motors.
Reduces the starting current of induction motors
Prevents excessive voltage drop in the power supply
Protects the motor windings from overheating
Allows for smooth and controlled motor starting
Commonly used in applications where high starting torque is not required
The OLTC (On-Load Tap Changer) in a transformer is typically connected to the high voltage side.
OLTC is connected to the high voltage winding of the transformer
It allows for tap changing while the transformer is energized
The low voltage side remains fixed while the high voltage side can be adjusted
Yes, OLTC is always connected in the HT voltage side.
OLTC stands for On-Load Tap Changer.
It is a device used in electrical power transformers to regulate the voltage level.
OLTC is typically connected on the high voltage (HT) side of the transformer.
It allows for tap changing while the transformer is energized and under load.
By changing the tap position, the OLTC can adjust the transformer's output voltage.
This helps to...
UV coil is a component used in HVAC systems to disinfect air by emitting ultraviolet light.
UV coil is installed in the air handling unit of HVAC systems.
It emits ultraviolet light to kill or deactivate microorganisms like bacteria, viruses, and mold spores.
UV light damages the DNA and RNA of these microorganisms, preventing them from reproducing.
UV coil helps improve indoor air quality by reducing the presence of harmf...
UV Coil provides protection against over voltage and under voltage.
UV Coil is a device used in electrical systems to protect against voltage fluctuations.
It monitors the voltage levels and activates when the voltage exceeds or falls below the specified limits.
When the voltage exceeds the upper limit, the UV Coil disconnects the power supply to prevent damage to the equipment.
Similarly, when the voltage falls below the ...
Top trending discussions
I applied via Company Website and was interviewed before Jan 2022. There were 3 interview rounds.
I appeared for an interview in Mar 2025, where I was asked the following questions.
Cable tray laying involves planning, installation, and securing cable trays for efficient cable management in electrical systems.
Assess the layout: Determine the optimal route for cable trays considering building structure and electrical load requirements.
Select appropriate materials: Use materials like aluminum or steel based on environmental conditions and load capacity.
Ensure proper support: Install trays with adequ...
Cables require proper termination and laying techniques for effective electrical performance and safety.
Types of cable terminations include crimping, soldering, and using connectors.
Cable laying methods include direct burial, conduit installation, and aerial installation.
For example, underground cables are often terminated with heat-shrinkable sleeves.
Aerial cables are typically laid using support structures like poles...
Load calculation is crucial for ensuring electrical systems can handle demand without failure.
Load calculation determines the total electrical demand of a system.
It considers various factors like lighting, HVAC, and equipment loads.
Example: In a residential building, lighting load might be calculated based on wattage per square foot.
Commercial buildings may require demand factors for peak load scenarios.
Accurate load c...
Effective project execution involves client discussions to identify and solve engineering problems collaboratively.
Initiated regular client meetings to discuss project milestones and address concerns.
Utilized feedback from clients to refine project specifications, ensuring alignment with their needs.
Implemented a problem-solving framework that involved brainstorming sessions with clients to tackle technical challenges.
...
I appeared for an interview before Jul 2024, where I was asked the following questions.
Bus bar schemes are different ways of connecting bus bars in power systems.
Single bus bar scheme
Double bus bar scheme
Main and transfer bus bar scheme
Ring bus bar scheme
Breaker and a half scheme
Mesh bus bar scheme
The equipment sequence for any line bay starts with the circuit breaker and ends with the transformer.
The circuit breaker is the first equipment in the sequence.
Next comes the isolator switch.
After that, the earth switch is operated.
Then the line disconnector is opened.
Finally, the transformer is disconnected from the line.
The sequence is reversed when the line bay is put back into service.
Yes, I am comfortable relocating for the right opportunity and to further my career growth.
I have previously relocated for a job, which helped me gain valuable experience in a new environment.
Relocating allows me to explore new cultures and expand my professional network.
I understand the importance of being flexible in today's job market, especially in engineering roles.
I am open to discussing relocation packages and s...
I applied via Walk-in and was interviewed before Apr 2021. There were 2 interview rounds.
It is the right choice if any one join this company and number one in competition
based on 9 reviews
Rating in categories
Assistant Manager
818
salaries
| ₹8.2 L/yr - ₹14 L/yr |
Deputy Manager
531
salaries
| ₹11.3 L/yr - ₹19.9 L/yr |
Senior Engineer
416
salaries
| ₹4.6 L/yr - ₹9.8 L/yr |
Quality Engineer
324
salaries
| ₹1.8 L/yr - ₹4.5 L/yr |
Manager
257
salaries
| ₹16 L/yr - ₹29 L/yr |