The refrigeration cycle used in a chilling plant is typically the vapor compression cycle.
The vapor compression cycle involves compressing refrigerant vapor to increase its temperature and pressure.
The high-pressure vapor then condenses into a liquid, releasing heat.
The liquid refrigerant then passes through an expansion valve, reducing its pressure and temperature.
The low-pressure liquid then evaporates, absorbin...
Yes, I have experience in boiler passing. It involves a thorough inspection of the boiler to ensure its safe and efficient operation.
Boiler passing involves a visual inspection of the boiler's exterior and interior components.
The inspection includes checking for leaks, cracks, corrosion, and other signs of wear and tear.
The boiler's safety controls, valves, and gauges are also checked to ensure they are functionin...
Air fuel ratio in boiler is the ratio of mass of air to mass of fuel. It is maintained by adjusting the fuel and air flow rates.
Air fuel ratio is critical for efficient combustion and minimizing emissions.
The ideal air fuel ratio for a boiler is typically between 1.5 and 2.5.
To maintain the air fuel ratio, the fuel and air flow rates must be adjusted based on the boiler load and combustion conditions.
Excess air ca...
Preventive maintenance of a reactor involves regular inspection, cleaning, and replacement of parts to ensure safe and efficient operation.
Regular inspection of reactor components such as valves, pumps, and pipes
Cleaning of reactor surfaces to prevent buildup of contaminants
Replacement of worn or damaged parts to prevent equipment failure
Testing of safety systems to ensure proper function in case of emergency
Monit...
A vapour compression cycle is a process used in refrigeration systems to remove heat from a space.
The cycle consists of four main components: a compressor, a condenser, an expansion valve, and an evaporator.
The compressor takes in low-pressure refrigerant gas and compresses it to high pressure.
The high-pressure gas then flows to the condenser, where it releases heat and condenses into a high-pressure liquid.
The li...
Gate valves and ball valves are two common types of valves used in industrial applications.
Gate valves have a sliding gate that controls the flow of fluid through the valve.
Ball valves have a rotating ball with a hole in the middle that controls the flow of fluid through the valve.
Gate valves are typically used for on/off control of fluid flow, while ball valves are used for throttling and control applications.
Gat...
Yes, chemical treatment is done in cooling tower to prevent scaling, corrosion and biological growth.
Chemicals like biocides, scale inhibitors and corrosion inhibitors are added to the water in cooling tower.
Biocides are used to prevent the growth of bacteria, algae and fungi.
Scale inhibitors are used to prevent the formation of mineral deposits on the tower walls and heat exchangers.
Corrosion inhibitors are used ...
Utility and process equipment capacity and make
Provide details of all utility and process equipment installed in the facility
Include information on their capacity and make
Utility equipment may include HVAC, compressed air, water treatment, etc.
Process equipment may include reactors, distillation columns, pumps, etc.
HVAC capacity and motor size are interdependent.
The HVAC capacity is determined by the size of the space it needs to cool or heat.
The motor size is determined by the HVAC capacity and the type of system being used.
For example, a small window AC unit may have a motor size of 1/6 horsepower, while a large central AC unit may have a motor size of 5 horsepower.
It is important to ensure that the motor size is appropria...
I applied via Referral and was interviewed in Oct 2021. There was 1 interview round.
A vapour compression cycle is a process used in refrigeration systems to remove heat from a space.
The cycle consists of four main components: a compressor, a condenser, an expansion valve, and an evaporator.
The compressor takes in low-pressure refrigerant gas and compresses it to high pressure.
The high-pressure gas then flows to the condenser, where it releases heat and condenses into a high-pressure liquid.
The liquid ...
In my previous company, we faced a significant breakdown in our HVAC system, which required immediate attention and a systematic approach to resolve.
The HVAC system failure occurred during peak summer, leading to uncomfortable working conditions.
We conducted a root cause analysis and discovered a malfunctioning compressor as the primary issue.
I coordinated with the maintenance team to replace the faulty compressor and ...
Preventive maintenance of a reactor involves regular inspection, cleaning, and replacement of parts to ensure safe and efficient operation.
Regular inspection of reactor components such as valves, pumps, and pipes
Cleaning of reactor surfaces to prevent buildup of contaminants
Replacement of worn or damaged parts to prevent equipment failure
Testing of safety systems to ensure proper function in case of emergency
Monitoring...
Utility and process equipment capacity and make
Provide details of all utility and process equipment installed in the facility
Include information on their capacity and make
Utility equipment may include HVAC, compressed air, water treatment, etc.
Process equipment may include reactors, distillation columns, pumps, etc.
Air fuel ratio in boiler is the ratio of mass of air to mass of fuel. It is maintained by adjusting the fuel and air flow rates.
Air fuel ratio is critical for efficient combustion and minimizing emissions.
The ideal air fuel ratio for a boiler is typically between 1.5 and 2.5.
To maintain the air fuel ratio, the fuel and air flow rates must be adjusted based on the boiler load and combustion conditions.
Excess air can lea...
Yes, chemical treatment is done in cooling tower to prevent scaling, corrosion and biological growth.
Chemicals like biocides, scale inhibitors and corrosion inhibitors are added to the water in cooling tower.
Biocides are used to prevent the growth of bacteria, algae and fungi.
Scale inhibitors are used to prevent the formation of mineral deposits on the tower walls and heat exchangers.
Corrosion inhibitors are used to pr...
HVAC capacity and motor size are interdependent.
The HVAC capacity is determined by the size of the space it needs to cool or heat.
The motor size is determined by the HVAC capacity and the type of system being used.
For example, a small window AC unit may have a motor size of 1/6 horsepower, while a large central AC unit may have a motor size of 5 horsepower.
It is important to ensure that the motor size is appropriate fo...
Gate valves and ball valves are two common types of valves used in industrial applications.
Gate valves have a sliding gate that controls the flow of fluid through the valve.
Ball valves have a rotating ball with a hole in the middle that controls the flow of fluid through the valve.
Gate valves are typically used for on/off control of fluid flow, while ball valves are used for throttling and control applications.
Gate val...
Yes, I have experience in boiler passing. It involves a thorough inspection of the boiler to ensure its safe and efficient operation.
Boiler passing involves a visual inspection of the boiler's exterior and interior components.
The inspection includes checking for leaks, cracks, corrosion, and other signs of wear and tear.
The boiler's safety controls, valves, and gauges are also checked to ensure they are functioning pro...
Top trending discussions
Troubleshooting line-ups involves systematic diagnosis, identifying root causes, and implementing effective solutions.
1. Identify the symptoms: Check for error messages or unusual behavior in the line-up.
2. Review logs: Analyze system logs for any anomalies or patterns leading to the breakdown.
3. Check connections: Ensure all physical and network connections are secure and functioning.
4. Isolate components: Test indivi...
I applied via Approached by Company and was interviewed in Sep 2023. There were 3 interview rounds.
I applied via Walk-in and was interviewed in Aug 2021. There was 1 interview round.
The mechanical engineering career goal objectives in Mylan are focused on ensuring efficient maintenance operations and improving equipment reliability.
Developing and implementing preventive maintenance programs to minimize downtime
Identifying and resolving equipment malfunctions to optimize production
Collaborating with cross-functional teams to improve equipment design and performance
Implementing cost-saving initiativ...
I applied via Recruitment Consulltant and was interviewed before Jun 2022. There were 5 interview rounds.
Basic questions with respect to your role
Checkpoints during breakdown
posted on 25 Jul 2021
I applied via Company Website and was interviewed before Jul 2020. There were 4 interview rounds.
There are several types of pumps used in mechanical engineering.
Centrifugal pumps
Reciprocating pumps
Rotary pumps
Diaphragm pumps
Gear pumps
Vane pumps
Screw pumps
Jet pumps
Peristaltic pumps
Piston pumps
The parts of a pump include impeller, casing, shaft, bearings, seals, and motor.
Impeller: Rotating component that imparts energy to the fluid.
Casing: Encloses the impeller and directs the flow of fluid.
Shaft: Transmits the rotational motion from the motor to the impeller.
Bearings: Support the shaft and reduce friction.
Seals: Prevent leakage of fluid along the shaft.
Motor: Provides the power to drive the pump.
I applied via Walk-in and was interviewed before Aug 2021. There was 1 interview round.
Answers to questions related to construction and engineering.
1) M25 ratio is a mix design ratio used in concrete construction.
2) Steel density is the mass per unit volume of steel.
3) Steel weight can be calculated by multiplying the volume of steel by its density.
4) Plastering ratio refers to the proportion of cement and sand used in plastering.
5) The number of bricks in 1 cubic meter depends on the size of the bricks.
I applied via Referral and was interviewed before Aug 2021. There were 3 interview rounds.
based on 7 reviews
Rating in categories
Assistant Manager
99
salaries
| ₹7.4 L/yr - ₹20 L/yr |
Executive
99
salaries
| ₹3 L/yr - ₹10.8 L/yr |
Senior Executive
87
salaries
| ₹4.6 L/yr - ₹12 L/yr |
Regulatory Affairs Associate
87
salaries
| ₹3 L/yr - ₹9.7 L/yr |
Manager
83
salaries
| ₹15 L/yr - ₹39.4 L/yr |
Hetero
Viatris
Abbott
Akums Drugs & Pharmaceuticals Limited