Filter interviews by
Process buildings focus on continuous operations, while non-process buildings serve supportive or administrative functions.
Process buildings are designed for manufacturing or production, e.g., chemical plants.
Non-process buildings include offices, warehouses, and maintenance facilities.
Examples of process buildings: refineries, power plants, and food processing facilities.
Examples of non-process buildings: adminis...
ACPH (Air Changes Per Hour) measures ventilation effectiveness in spaces, crucial for air quality and comfort.
ACPH is calculated by dividing the volume of air supplied by the volume of the room.
Example: A room with 1000 cubic feet and 2000 cubic feet per hour of air supply has 2 ACPH.
Higher ACPH values indicate better ventilation; typical values range from 4 to 12 for residential spaces.
In hospitals, specific ACPH...
Experienced freelance consultant with a focus on strategic planning and project management across various industries.
Over 5 years of experience in consulting for startups, helping them develop business strategies.
Worked with a healthcare client to streamline their patient management system, resulting in a 30% increase in efficiency.
Conducted market research for a tech company, leading to the successful launch of a...
Pipe sizing involves determining the appropriate diameter for chilled water, condensate, drain, and plumbing systems to ensure efficiency.
Chilled Water (CHW) pipes are sized based on flow rate and temperature drop; for example, a 4-inch pipe may handle 100 GPM.
Condensate Drain (CDW) sizing considers the volume of condensate produced; typically, 2-inch pipes are used for smaller systems.
Drain pipes must comply with...
Heat load software calculates thermal loads for HVAC systems, ensuring efficient climate control in buildings.
Used in HVAC design to determine heating and cooling requirements.
Examples include Carrier HAP, Trane Trace, and EnergyPlus.
Factors considered: building orientation, insulation, occupancy, and equipment.
Helps in optimizing energy efficiency and comfort levels.
Infiltration calculations assess water movement through soil, crucial for irrigation and drainage design.
Infiltration rate is the speed at which water enters the soil, measured in inches per hour.
Common methods include the double-ring infiltrometer and the single-ring method.
Factors affecting infiltration include soil texture, structure, moisture content, and vegetation.
For example, sandy soils have higher infiltr...
I appeared for an interview before Mar 2024, where I was asked the following questions.
Experienced freelance consultant with a focus on strategic planning and project management across various industries.
Over 5 years of experience in consulting for startups, helping them develop business strategies.
Worked with a healthcare client to streamline their patient management system, resulting in a 30% increase in efficiency.
Conducted market research for a tech company, leading to the successful launch of a new ...
Process buildings focus on continuous operations, while non-process buildings serve supportive or administrative functions.
Process buildings are designed for manufacturing or production, e.g., chemical plants.
Non-process buildings include offices, warehouses, and maintenance facilities.
Examples of process buildings: refineries, power plants, and food processing facilities.
Examples of non-process buildings: administrati...
Heat load software calculates thermal loads for HVAC systems, ensuring efficient climate control in buildings.
Used in HVAC design to determine heating and cooling requirements.
Examples include Carrier HAP, Trane Trace, and EnergyPlus.
Factors considered: building orientation, insulation, occupancy, and equipment.
Helps in optimizing energy efficiency and comfort levels.
Duct sizing software helps HVAC professionals design efficient duct systems for optimal airflow and energy use.
Calculates duct dimensions based on airflow requirements and system pressure.
Examples include software like Wrightsoft, Elite Software, and HVAC Duct Sizer.
Helps in compliance with building codes and energy efficiency standards.
Allows for quick adjustments and simulations to optimize designs.
Pipe sizing involves determining the appropriate diameter for chilled water, condensate, drain, and plumbing systems to ensure efficiency.
Chilled Water (CHW) pipes are sized based on flow rate and temperature drop; for example, a 4-inch pipe may handle 100 GPM.
Condensate Drain (CDW) sizing considers the volume of condensate produced; typically, 2-inch pipes are used for smaller systems.
Drain pipes must comply with loca...
ACPH (Air Changes Per Hour) measures ventilation effectiveness in spaces, crucial for air quality and comfort.
ACPH is calculated by dividing the volume of air supplied by the volume of the room.
Example: A room with 1000 cubic feet and 2000 cubic feet per hour of air supply has 2 ACPH.
Higher ACPH values indicate better ventilation; typical values range from 4 to 12 for residential spaces.
In hospitals, specific ACPH valu...
Infiltration calculations assess water movement through soil, crucial for irrigation and drainage design.
Infiltration rate is the speed at which water enters the soil, measured in inches per hour.
Common methods include the double-ring infiltrometer and the single-ring method.
Factors affecting infiltration include soil texture, structure, moisture content, and vegetation.
For example, sandy soils have higher infiltration...
15 days or earlier depending upon requirements.
I applied via Approached by Company and was interviewed before Oct 2022. There were 2 interview rounds.
Yes, I have experience with HVAC systems in institutional buildings.
Managed HVAC system installation and maintenance in university buildings
Performed regular inspections and troubleshooting of HVAC systems in hospitals
Collaborated with architects and engineers to design efficient HVAC systems for government buildings
I have experience with installing, testing, and pre-commissioning chiller plants up to 2700TR capacity for each project.
Installed chiller plants with a maximum capacity of 2700TR for multiple projects
Conducted testing and pre-commissioning activities for the chiller plants
Ensured proper functioning and efficiency of the chiller plants before commissioning
Handled projects involving large-scale chiller plant installation...
Top trending discussions
I applied via Naukri.com and was interviewed before Feb 2020. There were 5 interview rounds.
I applied via Company Website and was interviewed in Feb 2021. There was 1 interview round.
I applied via Recruitment Consultant and was interviewed in Dec 2020. There was 1 interview round.
Banking life in a relationship involves managing finances, joint accounts, and financial planning together.
Banking life in a relationship includes opening joint accounts to manage shared expenses.
Couples often make financial decisions together, such as applying for loans or mortgages.
Financial planning becomes a collaborative effort, with discussions on saving, investing, and budgeting.
Trust and transparency are crucia...
I applied via Referral and was interviewed before Aug 2021. There were 2 interview rounds.
I applied via Recruitment Consulltant and was interviewed before Feb 2021. There were 2 interview rounds.
I applied via Job Portal and was interviewed before Feb 2021. There were 2 interview rounds.
Dynamic professional with diverse experience in management, team leadership, and strategic planning, eager to contribute to organizational success.
Over 8 years of experience in management roles, leading teams to achieve operational excellence.
Successfully implemented a new project management system that increased efficiency by 30%.
Strong background in financial analysis, having managed budgets exceeding $1 million.
Prov...
based on 2 interview experiences
Difficulty level
Duration
based on 1 review
Rating in categories