Filter interviews by
Top trending discussions
I applied via Naukri.com and was interviewed in Jul 2024. There was 1 interview round.
I applied via Walk-in and was interviewed in Apr 2023. There were 3 interview rounds.
I applied via Walk-in
About your job, location, CTC
I applied via Walk-in and was interviewed in Apr 2023. There were 2 interview rounds.
Construction procedure involves planning, designing, obtaining permits, site preparation, foundation construction, framing, finishing, and inspections.
Planning and designing the project
Obtaining necessary permits
Site preparation and excavation
Foundation construction
Framing and structural work
Installation of utilities and systems
Finishing touches such as painting and flooring
Final inspections and approvals
Beam lapping position refers to the location where two beams overlap or intersect in a structural element.
Beam lapping position is important for ensuring structural integrity and load-bearing capacity.
Common beam lapping positions include end-to-end, side-by-side, and staggered lapping.
Proper beam lapping position is determined by engineering calculations and design specifications.
The tile procedure is a method used in computer graphics to fill a region with a repeating pattern or image.
The tile procedure involves dividing the region into smaller tiles and filling each tile with the desired pattern or image.
It is commonly used in graphic design software to create seamless textures or backgrounds.
The size and shape of the tiles can be adjusted to achieve different visual effects.
Examples of tile ...
posted on 16 Jul 2022
I applied via Referral and was interviewed before Jul 2021. There were 3 interview rounds.
BBS stands for Bar Bending Schedule. It is used in construction to provide details of reinforcement steel required for a particular concrete structure.
BBS is used to determine the quantity of steel required for a particular concrete structure.
It provides details of the diameter, length, and number of steel bars required for the structure.
BBS helps in estimating the cost of reinforcement steel for the project.
It ensures...
The foundation requirements for a substation depend on the type of equipment and soil conditions.
The foundation should be able to support the weight of the equipment and withstand any external forces such as wind or earthquakes.
The soil should be tested to determine its bearing capacity and settlement characteristics.
Common types of foundations include spread footings, mat foundations, and piles.
The foundation design s...
Yes, I am willing to relocate all over India for the right opportunity.
I am open to exploring opportunities in different parts of India.
I am willing to relocate for the right job and growth prospects.
I understand that relocation may be necessary for career advancement.
I am adaptable and can adjust to new environments and cultures.
For example, I have previously worked in different cities across India and have enjoyed th...
I applied via Company Website and was interviewed in Aug 2023. There was 1 interview round.
Cement grades indicate the strength and quality of cement, essential for construction projects.
Cement grades are classified based on their compressive strength, measured in megapascals (MPa).
Common grades include 33, 43, and 53, with 53 being the highest strength cement.
Grade 33 is suitable for general construction, while Grade 53 is used for high-strength applications.
Higher grade cement allows for thinner structures ...
M20 concrete mix ratio is 1:1.5:3, indicating 1 part cement, 1.5 parts sand, and 3 parts aggregate by volume.
M20 concrete is a nominal mix with a characteristic compressive strength of 20 MPa.
The mix ratio of 1:1.5:3 is commonly used for medium-strength structures.
For example, in a 1 cubic meter mix, you would use approximately 400 kg of cement, 600 kg of sand, and 1200 kg of aggregate.
Water-cement ratio is crucial; ty...
Water cement ratio is the ratio of the weight of water to the weight of cement used in a concrete mix.
Water cement ratio affects the strength and durability of concrete.
Lower water cement ratio results in stronger concrete but may be difficult to work with.
Typical water cement ratio ranges from 0.4 to 0.6 for normal strength concrete.
Excess water can lead to lower strength and durability of concrete.
posted on 15 Sep 2023
I applied via Job Portal and was interviewed in Aug 2023. There were 3 interview rounds.
The minimum cement content in RCC structure is typically around 300 kg/m3.
Minimum cement content is usually specified by structural engineers based on design requirements.
Higher cement content may be required for structures in aggressive environments or with special design considerations.
The minimum cement content is important for achieving the desired strength and durability of the concrete mix.
The shape of slump in a slump cone test is typically conical.
The shape of slump is conical, with the top being wider than the base.
The height of the slump is measured to determine the workability of the concrete.
Different types of slumps (true slump, shear slump, collapse slump) indicate different levels of workability.
Example: A true slump has a smooth, symmetrical shape with a slight collapse at the center.
Lapping zone of column is where two reinforcement bars overlap to ensure continuity of load transfer.
Lapping zone should be at least 50 times the diameter of the smaller bar away from the face of the support.
Proper lapping length is crucial for structural integrity and load distribution.
Lapping should be staggered in multiple layers for better strength.
Ensure proper cover and clear spacing around the lapping zone to pr...
I applied via Walk-in and was interviewed in Feb 2021. There were 3 interview rounds.
based on 3 reviews
Rating in categories
Site Engineer
86
salaries
| ₹1 L/yr - ₹4.6 L/yr |
Civil Site Engineer
54
salaries
| ₹1.1 L/yr - ₹4 L/yr |
Senior Engineer
22
salaries
| ₹3.2 L/yr - ₹7.5 L/yr |
Civil Engineer
14
salaries
| ₹1.5 L/yr - ₹4.5 L/yr |
Senior Site Engineer
9
salaries
| ₹3 L/yr - ₹5.1 L/yr |
Ramky Infrastructure
McNally Bharat Engineering
SYSTRA
Techno Electric & Engineering Company