i
AECOM
Work with us
Proud winner of ABECA 2025 - AmbitionBox Employee Choice Awards
Filter interviews by
I am available for the project and can commit to the required time and effort.
I am currently not committed to any other projects
I have the necessary skills and experience to contribute effectively
I am willing to adjust my schedule if needed for the project
I am excited about the opportunity to work on this project
Bending moment diagram of a 1-bay, 1-storey portal frame with point load at column middle.
Calculate reactions at supports
Determine internal forces at critical points
Plot bending moment diagram using equations or software
Identify maximum bending moment and its location
M stands for mix design in M-20 concrete, indicating the compressive strength of the concrete mix.
M-20 concrete is a mix design where 'M' represents the compressive strength of the concrete after 28 days of curing.
The number '20' in M-20 concrete indicates the characteristic compressive strength of concrete in N/mm^2.
Different grades of concrete have different compressive strength requirements, with M-20 being a c...
Dynamic method considers time history of earthquake while equivalent static method simplifies earthquake forces into equivalent static forces.
Dynamic method analyzes building response to actual time history of earthquake ground motion.
Equivalent static method simplifies earthquake forces into equivalent static forces based on simplified assumptions.
Dynamic method is more accurate but computationally intensive, whi...
Design process of one-way and two-way slabs and their differences
One-way slab design involves calculating bending moments and shear forces along one direction, typically supported on two opposite sides. Two-way slab design considers bending moments and shear forces in both directions, usually supported on all four sides.
One-way slab design is simpler and more common in practice, while two-way slab design is more c...
IS 10262 is required for mix design in civil engineering.
IS 10262 is the code for concrete mix design in India.
It provides guidelines for proportioning of concrete ingredients based on strength and durability requirements.
The code covers various aspects such as water-cement ratio, workability, and compressive strength.
Mix design is crucial for ensuring the desired properties and performance of concrete.
Following t...
Earthquake design of a multi storey building involves analyzing seismic forces, selecting appropriate structural systems, and implementing design measures to ensure safety.
Analyze seismic forces based on the building location and seismic zone
Select appropriate structural systems such as reinforced concrete or steel frames
Implement design measures like base isolation, dampers, and shear walls to enhance building's ...
Bending moment diagram of a fixed beam subjected to udl throughout the whole length.
Calculate the reactions at the supports of the beam
Determine the equation for bending moment at any point along the beam
Plot the bending moment diagram with positive and negative values
The bending moment will be maximum at the supports and zero at the midpoint of the beam
Transformers are sized based on load requirements and voltage levels.
Determine the load requirements of the system
Calculate the required kVA rating based on the load requirements
Determine the voltage levels of the system
Select a transformer with a kVA rating and voltage levels that meet the requirements
Consider factors such as efficiency, temperature rise, and impedance when selecting a transformer
DG sizing depends on load demand, backup requirements, fuel availability, and budget.
Calculate the total load demand of the system
Determine the backup requirements and duration
Consider the availability of fuel and its cost
Evaluate the budget for the project
Select a DG with appropriate capacity and efficiency
Perform a feasibility study and cost-benefit analysis
Consider environmental regulations and noise restrictio...
I appeared for an interview in Dec 2024, where I was asked the following questions.
I applied via Company Website and was interviewed in Oct 2024.ย There were 2 interview rounds.
Regarding RDSS Projects
I appeared for an interview in Mar 2025, where I was asked the following questions.
Cable tray laying involves planning, installation, and securing cable trays for efficient cable management in electrical systems.
Assess the layout: Determine the optimal route for cable trays considering building structure and electrical load requirements.
Select appropriate materials: Use materials like aluminum or steel based on environmental conditions and load capacity.
Ensure proper support: Install trays with adequ...
Cables require proper termination and laying techniques for effective electrical performance and safety.
Types of cable terminations include crimping, soldering, and using connectors.
Cable laying methods include direct burial, conduit installation, and aerial installation.
For example, underground cables are often terminated with heat-shrinkable sleeves.
Aerial cables are typically laid using support structures like poles...
Load calculation is crucial for ensuring electrical systems can handle demand without failure.
Load calculation determines the total electrical demand of a system.
It considers various factors like lighting, HVAC, and equipment loads.
Example: In a residential building, lighting load might be calculated based on wattage per square foot.
Commercial buildings may require demand factors for peak load scenarios.
Accurate load c...
I have knowledge in the field of mechanical engineering.
Mechanical engineering principles and concepts
Design and analysis of mechanical systems
Thermodynamics and fluid mechanics
I am not comfortable disclosing my past salary from my previous company.
It is not appropriate to discuss past salary during an interview
Focus on the value I can bring to this new role
Salary expectations should be based on the current market and the responsibilities of the new position
I worked at my past company for 3 years.
Worked at past company for 3 years
Started in entry-level position and was promoted twice
Received Employee of the Year award in second year
I expect a competitive salary that reflects my skills, experience, and the market rate for this position.
Research the average salary range for Engineer 1 positions in the industry and location
Consider your own qualifications, experience, and the value you bring to the company
Be prepared to negotiate based on the company's offer and benefits package
I appeared for an interview in Apr 2025, where I was asked the following questions.
I appeared for an interview in Jan 2025.
Written performance about the overall questions in time management.
How you would approach to solve a problem.
Top trending discussions
The duration of AECOM interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 101 interview experiences
Difficulty level
Duration
based on 1.7k reviews
Rating in categories
Gurgaon / Gurugram,
Bangalore / Bengaluru
+118-28 Yrs
Not Disclosed
Project Engineer
259
salaries
| โน5.5 L/yr - โน20 L/yr |
Senior Engineer
195
salaries
| โน8.2 L/yr - โน30 L/yr |
L2 Engineer
155
salaries
| โน3.4 L/yr - โน10.1 L/yr |
Engineer
132
salaries
| โน4 L/yr - โน14.5 L/yr |
Associate
116
salaries
| โน14 L/yr - โน45 L/yr |
Shapoorji Pallonji Group
Alstom Transportation
Saint-Gobain
AtkinsRealis