The least count of a dumpy level staff reading is typically 0.01 ft or 1 mm.
The least count is the smallest measurement that can be read on the scale of the dumpy level staff.
For most dumpy levels, the least count is 0.01 ft or 1 mm.
This means that the dumpy level can measure differences in elevation as small as 0.01 ft or 1 mm.
Concrete cover is provided for reinforcement to protect it from corrosion, fire, and other environmental factors.
Concrete cover protects reinforcement from corrosion by preventing exposure to moisture and aggressive chemicals.
It provides fire resistance by acting as a barrier between the reinforcement and the fire.
Concrete cover helps in maintaining the bond between reinforcement and concrete, ensuring structural integ...
Civil engineers at site are responsible for overseeing construction projects, ensuring they are completed safely, on time, and within budget.
Supervising construction activities to ensure compliance with design specifications and safety standards
Managing resources and materials efficiently to meet project deadlines
Collaborating with architects, contractors, and other stakeholders to resolve any issues that may arise
Cond...
Minimum concrete grade for RCC work is M20.
Minimum concrete grade for RCC work is M20 as per IS 456:2000.
Higher grades like M25, M30, M35, etc. can also be used depending on structural requirements.
Concrete grades indicate the compressive strength of concrete after 28 days of curing.
Higher grades are used for structures requiring higher strength like bridges, high-rise buildings, etc.
The density of unit weight of cement is typically around 1440 kg/m^3.
The density of unit weight of cement is commonly around 1440 kg/m^3.
This value can vary slightly depending on the type and brand of cement.
Density is a measure of mass per unit volume, in this case, kilograms per cubic meter.
The slump value of concrete for Normal RCC work is typically between 25-75 mm.
The slump value of concrete for Normal RCC work is usually around 50 mm.
The slump value can vary based on the specific requirements of the project and the mix design.
A higher slump value indicates a more workable concrete mix, while a lower slump value may be used for specialized applications.
It is important to test the slump value of concret...
I applied via Campus Placement and was interviewed in Mar 2022. There were 3 interview rounds.
Pre and post pendamic
Top trending discussions
I applied via Walk-in and was interviewed in Jun 2021. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in May 2021. There were 4 interview rounds.
I appeared for an interview in Feb 2025, where I was asked the following questions.
Testing pressure in plumbing systems ensures safety and functionality by identifying leaks and verifying system integrity.
1. Visual Inspection: Check for visible leaks or damage in pipes and fittings.
2. Pressure Testing: Use a pressure gauge to measure the system's pressure, ensuring it meets specified standards.
3. Hydrostatic Testing: Fill the system with water and pressurize it to check for leaks over a specified dur...
A single flat typically has several snag points that need to be addressed for safety and functionality before occupancy.
Structural Issues: Cracks in walls or ceilings can indicate underlying structural problems that need to be fixed.
Plumbing Leaks: Check for leaks under sinks or around toilets, which can lead to water damage if not addressed.
Electrical Faults: Ensure all outlets and switches are functioning properly to...
Vertical column stirrups typically have two bends to provide adequate support and confinement for the concrete.
Stirrups are usually made of steel bars bent into a U-shape.
Each stirrup typically has two bends at the ends to secure it to the main reinforcement.
The number of bends can vary based on design requirements, but two is standard for vertical columns.
For example, in a rectangular column, stirrups are placed at re...
I applied via Approached by Company and was interviewed in Oct 2023. There were 4 interview rounds.
In my previous role, I led engineering projects, focusing on system optimization and team collaboration, leaving for career advancement.
Led a team of engineers to develop a new software application that improved processing speed by 30%.
Managed cross-functional projects, ensuring timely delivery and adherence to quality standards.
Implemented Agile methodologies, which increased team productivity and reduced project turn...
I have managed diverse engineering projects, focusing on design, development, and team collaboration to deliver high-quality solutions.
Led a team of engineers in developing a scalable web application, improving performance by 30%.
Implemented Agile methodologies, resulting in a 25% increase in project delivery speed.
Conducted code reviews and mentoring sessions, enhancing team skills and code quality.
Collaborated with c...
I applied via Naukri.com and was interviewed before Aug 2023. There was 1 interview round.
A shunt relay in an ACB is used to provide protection against overcurrents by diverting excess current away from the main circuit.
Shunt relay is connected in parallel with the main circuit of the ACB.
It detects overcurrents and activates to divert the excess current through a shunt path.
This helps in protecting the main circuit from damage due to overcurrents.
Shunt relays are commonly used in Air Circuit Breakers (ACBs...
CoC in HVAC stands for Certificate of Conformance, which is a document certifying that a product meets specified requirements.
CoC in HVAC is a Certificate of Conformance that ensures a product meets specific requirements.
It is often required in HVAC projects to ensure quality and compliance.
CoC may include details such as product specifications, testing results, and manufacturer information.
Biological oxygen demand (BOD) and Chemical oxygen demand (COD) are important parameters in wastewater treatment plants.
Biological oxygen demand (BOD) is a measure of the amount of dissolved oxygen needed by aerobic biological organisms to break down organic material in water.
Carbonaceous oxygen demand (COD) is a measure of the amount of oxygen required to oxidize all the organic and inorganic matter in water.
BOD is a ...
A voltage monitoring relay is a device that monitors voltage levels and triggers an alarm or protective action if the voltage exceeds or falls below a set threshold.
Monitors voltage levels in electrical systems
Triggers alarm or protective action if voltage exceeds or falls below set threshold
Used to protect equipment from damage due to voltage fluctuations
WTP plant works on the principle of physical and chemical processes to remove impurities from water.
Water enters the plant and goes through processes like coagulation, flocculation, sedimentation, filtration, and disinfection.
Coagulation involves adding chemicals to water to make impurities clump together.
Flocculation helps in forming larger particles called floc for easier removal.
Sedimentation allows the floc to sett...
I provide daily and monthly reports on project progress, issues, and key metrics to track performance.
Daily reports include updates on tasks completed, challenges faced, and plans for the next day.
Monthly reports summarize overall progress, budget status, and any potential risks or delays.
Reports may also include key performance indicators (KPIs) such as project milestones achieved, budget variance, and resource utiliz...
based on 4 interview experiences
Difficulty level
Duration
based on 13 reviews
Rating in categories
Senior Engineer
94
salaries
| ₹3.5 L/yr - ₹9.5 L/yr |
Safety Officer
77
salaries
| ₹2.4 L/yr - ₹6.1 L/yr |
Assistant Engineer
54
salaries
| ₹3.5 L/yr - ₹6.5 L/yr |
Junior Engineer
45
salaries
| ₹2.4 L/yr - ₹4.3 L/yr |
Senior Civil Engineer
43
salaries
| ₹4.5 L/yr - ₹10.1 L/yr |
Sobha
Lodha Group
Cushman & Wakefield
Godrej Properties